Check the data sets imposed. 

 

Press the start button on the machine to which the Sumo pump is connected. 

 

Check pump start-up. 

 

Check that the machine is adequately lubricated (if there are still some doubts about its correct functioning you can contact 
the Dropsa S.p.A Technical Office and request a test procedure). 

 

check  that  the  direction  of  rotation  of  the  electric  motor  is  the  one  indicated  by  the  indicator  arrow,  positioned  on  the 
protective housing of the motor fan; 

 

Check that the hydraulic connection is correct. 

 

7.4 

ADJUSTMENT/ CALIBRATION OF LEVEL PROBES 

 

7.4.1 Pressure 

 

It is possible to adjust working pressure by rotating the bypass screw clockwise to increase pressure or anticlockwise to reduce 
pressure. During this operation pay attention to the pressure gauge positioned on the edge of the pump.

 

 

7.4.2 LASER PROBE SETTING, 24V CC OUT NO E NC (1 threshold)   
 

1.

 

Reference notch  

2.

 

Yellow  led:  lights  when  the  set  value  is  reached, 
(outlet=ON). 

3.

 

Lock ring  

4.

 

Setting lock ring (be adjusted manually after unlocking). 

5.

 

Green led: indicates the correct power supply (24V cc). 

 

 
 

 

* To obtain a correct setting bring the lock ring to maximum setting value and then down to desire value. 

 

On the pump is placed a label that shows the wiring diagram and setting values. The pump is normally equipped with pre setting 
sensor to "L" thresholds (minimum level).  Whereas other thresholds: MM (absolute maximum level), M (absolute level), LL 
(absolute minimum level), can be set 

by the user. 

 

 
 

 

 
 
 
 
 
 
 

 
 
 

 
 
 
 

7.4.3 Procedure for calibrating the capacitive probe (optional) 

 

Before being assembled the capacitive probe must be calibrated in accordance with the following sequence: 
1.

 

connect the sensor electrically; 

2.

 

immerse the sensor in the lubricant, down to half of its length; 

3.

 

remove the sensor from the lubricant until it skims the surface of the lubricant; 

4.

 

at this point there can be two possible types of operation: 

-

 

the  sensor  status  does  not  change:  its  sensitivity  must  be  reduced  (by  acting  on  the  screws  for  adjusting  sensor 
sensitivity) until its state of excitation is reached 

-

 

if its status changes, the sensor already possesses the correct sensitivity 

5.

 

after checking that the sensor has been correctly read, the sensor reading must be repeated at least three times 

6.

 

Tighten the capacitive probe on the probe carrier rod, complying with the following assembly height: 

-

 

450 mm (from below the cover up to the lower surface of the sensor) for a 30 kg tank 

-

 

900 mm (from below the cover up to the lower surface of the sensor) for a 100 kg tank. 
 

ATTENZIONE

è possibile impostare solo una soglia alla volta.

 

 

 

Summary of Contents for 2477000

Page 1: ...TICS 5 COMPONENTS 6 UNPACKING AND INSTALLING 7 OPERATING INSTRUCTIONS 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 PRE...

Page 2: ...ction from a set of components which are fully compatible and easy to assemble the pressure quantity of lubricant delivered actual type of lubricant or type of distribution can be altered This constru...

Page 3: ...ounted 30 Kg metal reservoir the system is complete with electrical control equipment that allows the pump motor control when the pressure exceed provided or in case of malfunction of the lubrificant...

Page 4: ...80 Kg with transparent reservoir made of polyethylene for special applications E A B C D E F 780 734 630 580 1410 335 A B C D E F PLASTIC GREASE RESERVOIR 148 5 14 DISTANCE BETWEEN HOLES WITHOUT PALLE...

Page 5: ...I 2 Max Degree of protection IP 55 Electric motor Three phase Power 0 75kW Protection IP55 class B Voltage 230 400 Volt 5 50 Hz 280 480Volt 5 60 Hz S1 continuous service N B do not supply the machine...

Page 6: ...Manifold group Refilling oil cap with filter 10 m Min max float level indicator Electropneumatic switch P N 0083450 Connection 1 2 BSP Connection 3 8 BSP Line 1 Line 2 SINGLE OUTLET GREASE PUMP option...

Page 7: ...of special high resistance steel which gives the pump better reliability and durability 5 3 INVERTORS CODE DESCRIPTION Series 0083420 Interchangeable electromagnetic inverter mounted as standard on S...

Page 8: ...s manufactured to sustain high pressures via a pressure chamber optimising the inverter operations two control electromagnets equipped with a thermal probe with an intervention temperature of 100 C pr...

Page 9: ...D MAXIMUM OIL LEVE Standard oil pumps have two types of level Minimum and maximum level float Maximum visual level float 5 6 1 Minimum and maximum level float A probe rod with dual float mounted on th...

Page 10: ...se by the supplier to fix the pump correctly check the pitch dimensions shown in the figures in chapter 12 Use safety gloves and goggles as indicated in the safety sheet for the lubrication oil Do NOT...

Page 11: ...On the pump is placed a label that shows the wiring diagram and setting values The pump is normally equipped with pre setting sensor to L thresholds minimum level Whereas other thresholds MM absolute...

Page 12: ...or in digital mode two outputs and four intervention thresholds We attach a table showing the calibration parameters for the laser probe for 30 and 100 kg tank Image 6 LASER PROBE CALIBRATION 30 kg t...

Page 13: ...for Laser probe 1 Press the MODE ENTER key once OU2 appears on the Display 2 Keep the SET button pressed down for 5 sec 3 When the wording on the Display no longer flashes press SET 4 times until Fno...

Page 14: ...ght by releasing the button the two LEDs have a fixed light 7 press the button for 3 or 4 seconds the probe has acquired the Maximum absolute level 8 In this way the sensor is calibrated N B green Led...

Page 15: ...ing to factory settings START Remove power END Release the button Press and hold the button while power is applied both LED flashing simultaneously Press the button for about 13 sec while the green LE...

Page 16: ...ill the tank N B If the tank was emptied without the electric signal for reaching the minimum level being given the minimum level contact must be checked Remove the cover from the tank and check that...

Page 17: ...incorrect Incorrect adjustment of the control pressure gauge The pressure value set is too high and the pressure adjustment valve bypass intervenes before the pressure gauge can be activated Incorrect...

Page 18: ...rease version with LASER level 24V cc Out NO e NC 1 threshold 0295131 for 30 100 kg 0 STANDARD oil version with floating Reed 0295150 for 30 kg 0295160 for 100 kg Variants Min max laser level kit 24V...

Page 19: ...I per non fare confusione con il numero 1 1 2 SPECIAL VERSIONS Equipment Description Code 400 cm 3 min grease pump 80Kg 176 lb transparent tank with inverter code 0083420 at 24 V DC 2477100 SUMO ATEX...

Page 20: ...Kit 30 kg VAR 5 0295140 Ultrasound level Kit 100 kg VAR 6 Maximum and minimum float level kit 30 kg oil 0295150 Maximum and minimum float level kit 100 kg oil 0295160 Grease loading filter 0295009 By...

Page 21: ...s indicated by at least 200 mm 7 87 in Image 13 Dimensions mm inches A 940 37 30 kg reservoir 1390 54 7 100 kg reservoir 1450 57 80 kg reservoir B 615 24 21 30 100 kg reservoir C 450 17 71 30 100 kg r...

Page 22: ...N 292 Application of the essential safety requirements Machine Dir 06 42 electrical safety stipulations EN 60204 1 See below a list of dangers which have not been completely eliminated but are conside...

Reviews: