Tundra II Furnace Installation and Operation Manual
37
2- From the thermostat connected to the existing furnace, connect 2 new wire (B) on the
R and W terminals of your thermostat and fix them to the terminal on the circuit board
labeled "I" (interlock) of the Add-On furnace (see
Figure 1
).
Figure 1
When the wood furnace receives the signal from the existing furnace’s thermostat calling
for heat, it will disconnect the damper motor, sending the wood furnace in low burn until
the call for heat from that thermostat is satisfied.
After the existing furnace’s thermostat is satisfied, the wood furnace will return under the
control of its own thermostat.
Use in thermostat mode
To ensure proper operation of the air inlet damper while connected to a thermostat, the
manual control switch must be maintained in the closed position. However, when a
thermostat is connected to the furnace, it is still possible to use the manual control switch
to open the air damper if desired. Even though you chose to control the furnace with a
thermostat it is still possible to use the manual control switch to open the air intake damper
if desired.
EXISTING
FURNACE
ADD-ON
FURNACE
Summary of Contents for DF02001
Page 30: ...Tundra II Furnace Installation and Operation Manual 30 ...
Page 63: ...Tundra II Furnace Installation and Operation Manual 63 11 Exploded diagram and parts list ...
Page 64: ...Tundra II Furnace Installation and Operation Manual 64 ...
Page 65: ...Tundra II Furnace Installation and Operation Manual 65 ...
Page 66: ...Tundra II Furnace Installation and Operation Manual 66 ...
Page 67: ...Tundra II Furnace Installation and Operation Manual 67 ...
Page 73: ...Tundra II Furnace Installation and Operation Manual 73 12 2 1 Technical data Tundra II ...
Page 74: ...Tundra II Furnace Installation and Operation Manual 74 ...