Tundra II Furnace Installation and Operation Manual
33
NOTE
IT IS POSSIBLE TO SEE THE TEMPERATURE READ BY THE RTD BY PRESSING
THE LEFT BUTTON ON THE DIGITAL DISPLAY AT THE BACK OF THE FURNACE.
7.3 Blower technical Data
The blower speed must conform to the recommendations of the Warm Air Heating and Air
Conditioning National Association and should respect the static pressure ranges in the
warm air plenum of the furnace
.
MODEL
(DIRECT DRIVE)
FLOW
TEMP
VAR.
BTU/ H
STATIC
PRESSURE
OPTIONAL
FILTER
VENT
MOT.
VIT.
(CFM)*
(°F)
(WOOD)
INCH OF
W.C.
(IN)
TUNDRA II
DCT-916-800-5
1/4
4
1800
115
125,000
0,2
20" x 15" x 1"
Blower speed
Static pressure (in. WC) / (Pa)
Flow (CFM)**
1
0.2 / 50
900
2
0.2 / 50
1000
3
0.2 / 50
1200
4
0.2 / 50
1400
Volts
Amps
Max Amps
Hertz
Watts
120
2.8
3.4
60
336
*Value as per blower manufacturer’s specs.
**These results were measured at the exit of plenum during laboratory tests. Results may
vary depending on the configuration and installation.
Summary of Contents for DF02001
Page 30: ...Tundra II Furnace Installation and Operation Manual 30 ...
Page 63: ...Tundra II Furnace Installation and Operation Manual 63 11 Exploded diagram and parts list ...
Page 64: ...Tundra II Furnace Installation and Operation Manual 64 ...
Page 65: ...Tundra II Furnace Installation and Operation Manual 65 ...
Page 66: ...Tundra II Furnace Installation and Operation Manual 66 ...
Page 67: ...Tundra II Furnace Installation and Operation Manual 67 ...
Page 73: ...Tundra II Furnace Installation and Operation Manual 73 12 2 1 Technical data Tundra II ...
Page 74: ...Tundra II Furnace Installation and Operation Manual 74 ...