Service Manual
rev 5.0 with software Ind1V022
On the table the highest value under
3000Hz is 2793Hz.
ESR use
If ESR is applied for 150% of
nominal speed, then the full ESR
pulse frequency is 1,5 * 1600Hz
= 2400Hz.
Suitable maximum overspeed
detection level is 25% =
3000Hz.
S2-2=OFF and S2-3=OFF are
according to normal speed settings.
Correct switch settings are S2-4=ON
and S3=4.
Encoder with 600 ppr or over needs both encoder channels connected.
Check from V4.8.2 that the
detection level is
2793Hz/2400Hz =116,4% of
ESR speed.