9
2.3
Specifications of CCES models
Inverter model
CCES-
102
CCES-
104
CCES-
202
CCES-
204
CCES-
207
CCES-
215
CCES-
222
CCES-
407
CCES-
415
CCES-
422
Applicable Motor Output (KW)
0.2
0.4
0.2
0.4
0.75
1.5
2.2
0.75
1.5
2.2
Rated Horsepower (HP)
1/4
1/2
1/4
1/2
1
2
3
1
2
3
Rated Current (A)
1.4
2.3
1.4
2.3
4.2
7.5
10.5
2.3
3.8
5.2
Rated Capacity (KVA)
0.53
0.88
0.53
0.88
1.6
2.9
4
1.7
2.9
4
Weight (Lbs.)
1.5
1.5
1.7
1.7
1.8
3.7
3.9
3.5
3.5
3.6
Input Max. Voltage
Signal phase
100~120V (+10%, -
15%), 50/60 Hz
(+/-5%)
Single phase 200~240V *
(10%, -15%), 50/60 Hz (+/-5%)
Single or three phase
200~240V *
(+10%, -15%), 50/60
Hz (+/-5%)
3 phase 380~460V (+10%, -15%),
50/60 Hz (+/-5%)
Output Max. Voltage
3 phase 200~240V in
accordance with 2
times input
3 phase 200~240V in accordance with input
3 phase 380~480V
in accordance with input
Input signal state
PNP type (source) input 12VDC provided; 120VAC with D61538 isolator; 24V with D61539 isolator standard.
Control Method
Sinusoidal wave PWM contol
Frequency
control
Frequency control range
1~200Hz
Frequency setting
resolution
Digital: 0.01Hz (0~99.9Hz); 1Hz (100~200Hz)
Analog: 1.0Hz / 60 Hz
Keypad setting method
Directly via up and down arrow keys for adjustment.
Frequency setting signal
1-3 preset speeds. Analog 0~10V, 0~20mA, 4-20mA, 2 step and 3 step infinitely variable.
Frequency limit
Frequency upper / lower limit
Control
characteristics
Accel / Decel time
0.1~30 Seconds
V/F pattern
4 patterns for 50 or 60 Hz motors
Multifunction inputs
2 programmable inputs of the following : Ramp and hold,
Speed 2 and Speed 3 command, Emergency Stop, External base block, Reset command, Creep, Top Limit
Multifunction outputs
1 NO output contact of the following : fault, running output, frequency arrival, at current detect, at frequency detect.
Braking torque
20% standard. 100% with optional DB unit and resistor.
20% standard, 100% with external resistor
Built-in Function
Deceleration or Free run to stop, Auto reset, DC injection frequency / time / level select. Analog 0-10VDC frequency
output.
Digital operator monitor
3-digit 7 segment display frequency / function constants / fault history / CPU version
Ambient temperature
-10 ~ 40°C with cover. -10~50°C Chassis
Humidity
0 ~ 95% RH (non-condensing)
Vibration
Under 0.5G
EMC
Unfiltered
Class A (Filter built-in) optional
Class A (3 phases. Filter built-in)
optional
Enclosure
Protected chassis, IP20
UL
UL 508
Protective
Functions
Overload
150% 1 minute
Overvoltage
DC bus exceeds 410V
DC bus exceeds 800V
Undervoltage
DC bus drop below 200V
DC bus drop below 400V
Momentary power loss
Ride through 0~2 seconds, depending on load.
Stall prevention
During Acceleration / Deceleration / Constant speed
Output short circuit
Provided by electronic circuit
Ground fault
Provided by electronic circuit
Other protection
Heat sink fin overheat, current limit
Dimension (inches) H x W x D
5.2" x 2.8" x 4.6"
5.2" x 2.8" x 4.6"
5.63" x 4.65" x 6.8"
5.63" x 4.65" x 6.8"
Mounting Dimension (inches) H x W
4.6" x 2.4"
4.6" x 2.4"
5.01" x 4.25"
5.01" x 4.25"
Installation
Panel mounted or using DIN rail (Option)
* Single phase drives may be connected to three phase AC line voltages by connecting terminal L1/L to phase
A, L2/N to phase B and leave phase C disconnected and insulated. You may wish to rotate the phases in areas
where there are many single phase drives.