24
3.3 Parameter function description
F_00
Factory adjustment parameter. Do not change.
F_01
: Acceleration time.
Range= 00.1 ~ 30.0 sec
F_02
: Deceleration time.
Range = 00.1 ~ 30.0 sec
1. Acceleration / Deceleration time calculation formula: Basis= 60 Hz
Accelerate time = F_01 x
Setting Frequency
60 Hz
Decelerate time = F_02 x
Setting Frequency
60Hz