background image

drive.web automation

Installation & Operation Manual 

Contents

   

 

 

 

 

 

 

 

 

     

   

 

Page 

Design Statements, Warnings

   

 

 

 

 

 

 

1, 2 

smarty

 

Models, Standard Features

 

 

 

 

 

 

2

 

Carrier

 Ratings and Features

   

 

 

 

 

 

 

2, 3 

smarty

 

Software and XIO Options

  

 

 

 

 

 

smarty

 

Installation and Front Panel

   

 

 

 

 

Carrier

 

Terminals, Dimensions, and Data

  

 

 

 

4, 5, 6 

smarty

 

Terminals, Ratings, and IO Functions    

   

 

Get 

savvy

®

,  USB Plug and Play, Ethernet Networking

 

 

 

8, 9 

Get started with 

savvy

 

engineering & design software 

 

9, 10 

Upgrade 

savvy

 

and

 

smarty

,

 

savvy-SFD

 

Upgrade

   

 

10

 

savvyPanel

®

 

Touch Screen Operator Station

   

 

 

10, 11 

smarty

 Precision Motion Functions and Connections

   

12 

smarty 

Comms Interfaces, Modbus, EIP 

   

 

       

  

12 

Free

 

drive.web

 

Online Training Seminars

   

 

 

 

12

 

Certification Statements

This process control equipment to be supplied by Class2, LPS, limited power supply. 

Design Statements

EMC  Standard,  EN  61326-1:  2006,  Electrical  Equipment  for  Measurement,  Control  and 

Laboratory Use. 

 

Emissions Class A, Commercial Equipment. 

 

Immunity Table 2, Industrial Equipment. 

LVD  Standards,  EN  61010-1:  2010,  Safety  Requirements  for  Electrical  Equipment  for 

Measurement, Control and Laboratory Use and;  

 

EN 61010-2-030: Particular Requirements for Testing and Measuring Circuits. 

smarty

 is an industrial controller designed for permanent installation by qualified professionals. 

If  it is used in a manner not specified herein the protection provided may be impaired. 

smarty

 

and its packaging contain recyclable materials 

This  device  is  designed  to  comply  with  Part  15  of   the  FCC  Rules.  Operation  is  subject  to  the  following  two 

conditions: (1)This device may not cause harmful interference, and (2)this device must accept any interference 

received, including interference that may cause undesired operation. 

This Class [A] digital apparatus is designed to comply with Canadian ICES-003.   Cet appareil numerique de la 

classe [A] est conforme à la norme NMB-003 du Canada. 

Warning!

 

It is essential that you read and understand this entire manual and the entire contents of  the 

savvy

 

software 

Help

 menu before proceeding with your installation and configuration. See page 6 for 

savvy

 

installation 

instructions. For more information and to download manuals and software, go to

 www.driveweb.com

 or contact 

us. See page 12. 

Warning! 

Your use of  

savvy

 

software and 

drive.web

 

devices may cause motors and machinery to power up 

with  high  Voltages  or  start  or  operate  in  an  unexpected,  dangerous  or  lethal  way.  It  is  essential  that  you  are 

completely  familiar  with  all  of   the  equipment  and  the  system  design  before  attempting  to  program  or  edit  a 

program or connect to any live device. It is also essential that a risk assessment is conducted to identify hazards. 

Risks must be reduced to tolerable levels.

smarty

 

HG503894Beta13

 

 

www.driveweb.com

              

              

Page 

#

/12

1

drive.web

SMARTY,  SAVVY,  SAVVYPANEL,  SPEEDY,  BARDAC,  and  DRIVE.WEB  are  trade  marks  of   Bardac 

Corporation, registered in the U.S. and other countries. 

®

Universal Automation Controller

dw240, dw241, 

dw244,  

dw248, & dw249

models

smarty

Summary of Contents for smarty dw240

Page 1: ...kaging contain recyclable materials This device is designed to comply with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This Class A digital apparatus is designed to comply with Canadian ICES 003 Cet appa...

Page 2: ...ROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Product Identification smarty Cassette Models smarty is a programmable device ...

Page 3: ...coder input 5 5VDC max 0 5VDC min 0 3VDC minimum differential Voltage Up to 1MHz ModbusRTU serial port is brought out to terminals instead of the jack in C2 smarty C4 Carrier 4 Ratings and Features adds to C3 Two 4 20mA current inputs Also 0 20mA 20 4mA and 20 0mA 100Ω input impedance Maximum input is 25mA 2 5VDC Six frequency event digital inputs 30Vmax 100kHz Replaces FT on C3 Seven frequency st...

Page 4: ...n and blinks for activity 100BaseTX Green LED when 100BaseTX connection is made Carriers C1 and C2 Terminals and Dimensions smarty HG503894Beta13 www driveweb com Page 12 4 use in order only ctual size hite beyond 02441 for ol Gray 99 00mm Ref ue Drawing Title Drawn by Property of smarty front label art Ian Bardwell Jones Bardac Corp drive web smarty 100 1 2 PoE lOlOl r use in order only actual si...

Page 5: ...V A B Carrier C3 Terminals and Dimensions Realtime Clock Battery CR2032 Realtime clock will be maintained for approximately 24hrs with no backup battery 4P4C XIO Port 8P8C CANopen Serial Port Width Overall 140mm 5 51 Height Overall 87mm 3 43 DINrail release clip Overall Height Back Panel to Front Panel 75mm 2 95 DI Digital Input DO Digital Output AO Analog Output AI Analog Input 1A Encoder 1 Chann...

Page 6: ...5 TO7 0V 0V 0V 0V 0V 0V 0V 24V 0V 24V 0V A B 0V 1A 1A 1B 1B 0V 2A 2A 2B 2B Carrier C4 Terminals and Dimensions 4P4C XIO Port 8P8C CANopen Serial Port Width Overall 210mm 8 27 Height Overall 87mm 3 43 DI Digital Input DO Digital Output AO Analog Output AI Analog Input CI Current Input 1A Encoder 1 Channel A 1B Encoder 1 Channel B 1Z Encoder 1 Marker 5V 5VDC Power Output FI Frequency Input TPW Power...

Page 7: ...o the unit depending on the installation Signal Wiring Notes Use twisted pair wiring for encoder and serial differential signals Outside metal enclosure use shielded cable with individually shielded twisted pairs such as Belden 8163 Ground shield at one end with a 360 ground clamp where cable enters quiet metal enclosure Separate wiring from AC power cables or RF noise sources smarty I O Functions...

Page 8: ...s for each drive web device and the host computer For systems with more than one drive web device use an Ethernet switch for all drive web devices and computer Get started with savvy We strongly recommend attending our free online training seminars See page 12 We strongly recommend you read the User Manual and Getting Started Guides under the Help menu Use Create Phantom in the Directory menu to e...

Page 9: ... Import Export Device Data Load save configuration data to from this smarty only Unlock Lock Set Password Choose Restrict Modification to allow viewing the configuration or Restrict All Access Click the smarty icon to view the device configuration Function Block Engine Window FBE Menu Standard savvy no SFD Add function blocks in the order to be processed Processing order is left to right top to bo...

Page 10: ...n blocks and connections is at the left of the Signal Flow Diagram showing program execution order from top down Change execution order by dragging function blocks up or down the list In this picture ENC1 Speed function block is moved so that it is processed after ENC Phase Lock savvyPanel Operator Station Computers Apple mobile digital devices iPad iPhone and iPod Touch are operator touch station...

Page 11: ... in Java based savvyPanel Appears as graphic tile in iOS Function blocks enable savvyPanel actions Alarm Annunciator Provides a system wide alarm annunciation when active Touch to view page 255 Presence Monitor Indicates the presence of a tagged savvyPanel application viewing a particular page Latch and SR Latch For lighted start stop pushbuttons Setpoint Monitor Adjust meter and setter range Dual...

Page 12: ...t write or force parameters that are read only or have incoming drive web connections Click the Comms Server icon in the FBE or SFD view dwOption 04 ModbusTCP IP slave server Supported Modbus Function Codes 1 thru 6 15 and 16 Supports up to five simultaneous clients masters dwOption 25 EIP PCCC Server Supports PLC5 Typed Write and Typed Read commands See Appendix B of the savvy User Manual for inf...