07-01913F F515 

Dri-Eaz Products, Inc. 

 

Owner’s Manual 

PHD 200 Dehumidifier 

Model F515 

DRI-EAZ PRODUCTS, INC.  

15180 Josh Wilson Road, Burlington, WA 98233 

Phone: 800-932-3030

 

Fax: 360-757-7950  

The Dri-Eaz

®

 PHD 200 Dehumidifier reduces humidity in enclosed environments by removing water vapor 

from the air. The PHD 200 is ideal for crawlspace drying, humidity control and other applications requiring 
high-performance dehumidification. (Not intended for professional water damage restoration.) 

Patents: http://www.LBpatents.com 

S A V E   T H E S E   I N S T R U C T I O N S

 

 

 

 

 

 

 

 

 

 

SAFETY INSTRUCTIONS 

WARNING! Do not alter or modify your unit in any 
way. Use only replacement parts authorized by 
Dri-Eaz Products, Inc. Modifications or use of unap-
proved parts could create a hazard and will void 
your warranty. Contact your authorized distributor 
for assistance. 

WARNING! Electric shock hazard, rotating fan, hot 
surface hazards. Unplug unit before opening cover 
for cleaning or servicing. Unit must be grounded. 

  Inspect the power cord before use. If cord is dam-

aged, do not use. Always grasp the plug (not the 
cord) to unplug. 

  Insert three-prong plug on power cord into a match-

ing electrically grounded outlet. Do not use adapter. 
Never cut off third prong. Do not use an extension 
cord.  

  The unit must be operated on a 115V/60Hz circuit 

protected by a Ground Fault Circuit Interrupter 
(GFCI) device.  

  Keep motor and wiring dry. 

  Do not attempt to repair the unit. For Authorized 

Service Centers, contact Dri-Eaz.  

BEFORE YOU BEGIN 

Warranty registration 

Visit 

warranty.drieaz.com

 to register your purchase. 

Registration allows us to better assist you with using, 
maintaining or servicing your equipment and to contact 
you in case we have important safety information con-
cerning your Dri-Eaz product. If you determine service is 
required, have your equipment model, serial number and 
original proof of purchase available and call your distrib-
utor for assistance with obtaining a return material au-
thorization (RMA). 

 

INTRODUCTION 

The PHD 200 Dehumidifier reduces humidity in enclosed 
structural environments by removing water vapor from 
the air. With proper use, the PHD 200 can help to dry out 
damp structural materials, insulation, and contents, and 
maintain a healthy level of humidity. Using the PHD 200 
may also prevent secondary damage caused by high hu-
midity. 

WARNING

 

CORRECT PLUG REMOVAL 

Grasp IEC plug and pull straight out

 

 

IMPORTANT: Damage to IEC receptacle or dehu-
midifier resulting  from  improper  removal  of the 
power cord is not covered by warranty. The IEC 
power cord is a wear item and is not covered by 
warranty. 

Summary of Contents for F515

Page 1: ...adapter Never cut off third prong Do not use an extension cord The unit must be operated on a 115V 60Hz circuit protected by a Ground Fault Circuit Interrupter GFCI device Keep motor and wiring dry Do...

Page 2: ...use a bucket or other container for water collection check it regularly to prevent over flows NOTICE Uncoil and straighten the entire drain hose Do not leave any part of the hose coiled and do not pl...

Page 3: ...y and the machine will begin operation immedi ately DISPLAY MENU Press to cycle through the display of additional dehumidifier conditions and User Settings To return to the main menu press the ON OFF...

Page 4: ...OUTLET 100 80 115 30 For information only 3 GRAIN DPR XX GPP XX X g kg for 230V models 4 FILTER CLEANED XXX HRS 5 FILTER CLEANED 0 HRS Press to clear filter hours 5 COIL CLEANED XXX HRS 5 COIL CLEANED...

Page 5: ...area 3 Press the PURGE key When the purge cycle is complete turn the unit off 4 Remove the external drain hose drain it carefully coil it and secure it with one of the straps provided on the side of t...

Page 6: ...in to stop if needed SYSTEM MESSAGES The Control Panel will display the following messages based on system performance and environmental conditions User action if any is required is indicated in the t...

Page 7: ...r ER4 OULET SENSOR CONNECT Temp sensor is open missing or shorted Check that temp sensors are installed cor rectly on control panel If error persists contact service ER5 SENSOR CONNECTION ON BD Inlet...

Page 8: ...rometer Increase room temperature Check filter Clean or replace as necessary Check heat exchange block and coils Clean as necessary If the problem you are experiencing is not listed here call your loc...

Page 9: ...cable de alimentaci n en un tomaco rriente con descarga a tierra adecuado No use adaptadores Nunca corte la tercera clavija No use cables prolongadores La unidad debe utilizarse en un circuito el ctr...

Page 10: ...a Ubicaci n del deshumidificador Para obtener los mejores resultados utilice los deshumi dificadores en un rea cerrada Coloque el deshumidifi cador lejos de obstrucciones y mant ngalo alejado de cualq...

Page 11: ...del panel de control que se encuentra m s ade lante Mensajes de error Si el diagn stico incorporado al PHD 200 detecta un problema la unidad mostrar un mensaje de error Con sulte Mensajes del sistema...

Page 12: ...a presionando DIS PLAY MENU MEN DE PANTALLA Con cada pulsa ci n del bot n se mostrar el siguiente par metro vea la lista m s adelante Cuando llegue al par metro que quiera ajustar presione MENU SELECT...

Page 13: ...ENTRADA SALIDA 100 80 115 30 S lo para informaci n 3 ENTRADA SALIDA XX X g kg 4 FILTRO LIMPIAR XXX HR 5 FILTRO LIMPIAR 0 HRS Presione para borrar las horas de limpieza del filtro 5 LIMPIAR BOBINA XXX...

Page 14: ...cuidado enr llela y suj tela con una de las tiras al costado de la unidad TRANSPORTE Y ALMACENAMIENTO AVISO Manipule la unidad con cuidado No la tire ni la apoye en lugares donde pueda caerse Si no tr...

Page 15: ...y posibles lesiones a los ocupantes del veh culo PROGRAMA DE MANTENIMIENTO ADVERTENCIA PELIGRO DE DESCARGA EL C TRICA Desconecte la unidad antes de limpiarla o darle mantenimiento ADVERTENCIA Riesgo d...

Page 16: ...ware del tablero de con trol Ninguna FXXX XXX N mero de modelo Ninguna APAGADO La unidad ha terminado de encender y est funcionando Ninguna POR FAVOR ESPERE RETAR COMPRS XX 60s de espera antes de que...

Page 17: ...n instalados correctamente en el panel de control Si el error persiste comun quese al centro de servicio ER5 CONEXION SENSOR TABLERO Sensor de temperatura humedad relativa de entrada abierto faltante...

Page 18: ...edad con un higr metro Aumente la temperatura de la habitaci n Controle el filtro L mpielo o reempl celo si es necesario Controle el bloque de intercambio de calor y los serpentines L mpielos si es ne...

Page 19: ...s la terre V rifier l tat du cordon d alimentation avant utilisation Ne pas l utiliser si le cordon est en dommag Pour d brancher toujours saisir la prise et non le cordon Enfoncer les trois fiches de...

Page 20: ...shumidifi cateur l cart de toute obstruction et de tout ce qui pourrait bloquer la circulation d air d entr e et de sortie de l appareil Pour plus d informations sur la cr ation d un environnement de...

Page 21: ...aucun compte rebours pour le compresseur n est affich un d lai n est pas n cessaire et l appareil commencera fonctionner imm diatement MENU D AFFICHAGE Appuyer pour faire d filer l affichage pour des...

Page 22: ...100 80 115 30 Pour information seulement 3 ENTRADA SALIDA XX X g kg 4 FILTRO LIMPIAR XXX HR 5 FILTRO LIMPIAR 0 HRS Appuyer sur pour effacer les heures du filtre 5 LIMPIAR BOBINA XXX HRS 5 LIMPIAR BOB...

Page 23: ...ttendez que le tableau de commande reprenne son af fichage normal avant de continuer 2 Basculez l g rement la machine pour s assurer que l eau restant sur les surfaces int rieures s coule dans le puis...

Page 24: ...A TA PADA BOMBA MANGUERA le clapet anti retour et le r servoir de la pompe peuvent avoir besoin d tre netto y s Retirer les grilles et le couvercle comme indiqu sur la figure B Retirer les vis de la b...

Page 25: ...ROSTATO ENTRADA XXX C XX Premi re ligne indique que l unit est en mode hygros tat Seconde ligne Alterne entre la temp rature d entr e et RH d entr e toutes les 2 secondes Aucune BAJA TEMP ENTRADA XXX...

Page 26: ...emp rature sont install s correctement sur le panneau de commande Si l er reur persiste contacter le fournisseur de services ER5 CONEXION SENSOR TABLERO Le capteur de la temp rature Rh d entr e est ou...

Page 27: ...ambiante V rifier le filtre Le nettoyer ou le remplacer si n cessaire V rifier bobines Les nettoyer si n cessaire Si le probl me que vous rencontrez ne figure pas dans ce tableau veuillez contacter vo...

Reviews: