07-01583B  06-07  Copyright 2007 Dri-Eaz Products, Inc. 

 

T

EST 

T

HERMOSTAT

:

 

1.  Move the system switch from OFF to the HEAT position. 

Press the 

button on the keypad until the setpoint 

temperature setting is a minimum of 3 degrees higher than 
the current room temperature. The EB1400 should start 
within several seconds. 

2.  The system switch in the OFF position. The EB1400 

should stop within several seconds on normal single stage 
heating or cooling systems. 

Note:

 On refrigeration 

systems you must wait 5 minutes for the automatic 
compressor short cycle protection period to expire, or 
press the RESET button to bypass this feature for initial 
testing purposes. Pressing the RESET button will erase 
any user program settings. 

3.  Place the system switch in the COOL position. 

4. Press 

the 

v

 button on the keypad until the setpoint 

temperature is a minimum of 3 degrees lower than the 
current room temperature. The cooling system should start 
within several seconds. 

 

5.  Place the fan switch in the AUTO position when using the 

EB1400. 

V

IEWING 

S

ET 

T

EMPERATURE

 

1.  Press and hold 

^

 or 

v

 button. The current setpoint 

temperature will be displayed in the place of the current 
room temperature, and the indicator SET will be displayed. 

2.  The display will return to normal operating mode when the 

^

 or 

v

 buttons are released. The SET indicator will turn off, 

indicating that the current temperature shown in the 
display is the room temperature. Continuing to hold the 

^

 

or 

v

 button for 3 seconds or longer will allow the user to 

change the current setpoint temperature (See Changing 
Set Temperature, below). 

C

HANGING SET 

T

EMPERATURE

 

1.  Press and hold 

^

 or 

v

 button for 3 seconds. The entire 

display will flash once and the SET indicator will be 
flashing. Release the 

^

 or 

v

 button and press the 

^

 or 

v

 

button again as desired to adjust the set temperature. 

2.  The display will return to normal operating mode after 5 

seconds. 

3.  The SET indicator will turn off in the display, indicating that 

the current temperature shown in the display is the room 
temperature. 

H

IGH 

T

EMPERATURE 

S

AFETY 

S

WITCH

 

When the selector switch is set to HEAT, a software feature 
automatically turns the unit off if the room temperature rises 
above 93°F (34°C). If the temperature rises above 99°F 
(37°C), the thermostat mechanically turns the unit off.  

N

ON

-V

OLATILE 

M

EMORY

 

In the event of a power failure, the non-volatile memory feature 
of this unit allows all settings to be recovered. When AC power 
is restored after an outage, all settings are retrieved from 
memory and reinstated. 

 

 

R

ESETTING 

T

HERMOSTAT

 

The Reset feature allows the user to completely reset the 
thermostat to return to factory-set software settings. 

1. To erase all entered settings, gently press RESET button 
using a paper clip or a small pencil tip. 

2. This will return all thermostat settings to their default values 
and register all new manual switch settings for proper 
operation.  

 

D

UCTING 

I

NSTRUCTIONS FOR THE 

EB1400: 

D

UCT 

A:

 

H

EAT 

I

NLET

 

D

UCT 

B:

 

H

EAT 

O

UTLET

 

D

UCT 

D:

 

C

OLD 

O

UTLET

 

 

 

D

UCTING

: The unit is ductable for directing 

conditioned air or heat into specific spaces. 

 

D

UCTING 

S

IZE

: Use 8-inch diamater ducting and 

secure with clamps on duct adapters. 

 

S

IDE 

D

UCTING

: When using duct on the side, 

ducting should be run sideways out doors and 
windows. Put unit in corner and duct up at an 
angle into ceiling tiles (not directly up). 

 

R

IGID 

D

UCTING

:

 

 Duct A requires rigid ducting (not  

layflat) attached by clamps. 
 

A

PPLICATIONS 

(Visit the EB1400 VTC at):  

http://www.dri-eaz.com/VTC/EB1400.html

 

 

C

OOLING 

I

MMEDIATE 

A

REA

: Cold air blowing from 

Duct D (not ducted) will cool overall room.  

 

H

EATING 

A

REA

:

 

Duct B outputs heat; ducting is 

needed if ducting warm air outside room or to 
focus heat in targeted area. If not ducted outside 
the room then it will heat the immediate space.  

 

N

EUTRAL 

A

IR 

C

ONDITIONING

: For neutral air 

conditioning duct both B (heat outlet) & A (heat 
inlet) outside the structure. 

 

D

EHUMIDIFYING

:

 

Spot cool with dehumidification by 

ducting outlet D. No ducting is needed to 
dehumidify overall area.  

 

S

POT 

C

OOLING

: For spot cooling point outlet D air 

stream to specific area or duct it to spot cool. 

 

T

RANSPORTING AND 

S

TORING

 

1.  Before transporting, move Duct B ducting adapter to either 

the front or back of the unit to prevent damage. 

Note:

 Do 

not expose the thermostat to moisture and rain when 
transporting in uncovered vehicles such as flatbed trucks. 

2.  Transport the unit on stairs or over rough surfaces upright 

on the Unimover or hand truck and hold in place using 
straps.

 WARNING!

 Take care when loading the unit on a 

hand truck; the unit could tip over resulting in personal 

Summary of Contents for EB1400

Page 1: ...r place where it could fall Rough treatment can damage the unit and may create a hazardous condition or void the warranty Inspect the power cord before use If cord is damaged do not use Replace with a cord of the same type and amperage rating Protect cord from damage by turning off unit before unplugging Always grasp the plug not pulling on the cord to unplug The unit is designed to operate on a 1...

Page 2: ...the cooling system from short cycling This thermostat automatically provides a 5 minute delay after turning off the cooling system output to protect the compressor This protection is also present while operating the unit in heating applications Important Notes If unit loses power or gets unplugged during operation operator MUST wait 5 minutes before plugging unit back in or risk damaging the compr...

Page 3: ... above 93 F 34 C If the temperature rises above 99 F 37 C the thermostat mechanically turns the unit off NON VOLATILE MEMORY In the event of a power failure the non volatile memory feature of this unit allows all settings to be recovered When AC power is restored after an outage all settings are retrieved from memory and reinstated RESETTING THERMOSTAT The Reset feature allows the user to complete...

Page 4: ...ction Inspect exterior components and make sure they are properly installed Listen to the unit for abnormal sounds For Parts and Service call your local distributor or the Dri Eaz Service Department at 800 932 3030 or 360 757 7776 2 Clean Exterior Clean the housing with a damp cloth Bring back the original shine with a vinyl cleaner polish like those used on automobile plastics 3 Inspect Back Filt...

Page 5: ...a unidad siempre sobre una superficie estable y nivelada No la deje caer la tire ni la coloque en un lugar donde pueda caerse La manipulación brusca puede dañar la unidad y dar lugar a una situación peligrosa o invalidar la garantía Inspeccione el cable de alimentación antes de usar Si el cable está dañado no lo use Cámbielo por un cable del mismo tipo y amperaje nominal Proteja el cable de los da...

Page 6: ...presor para evitar que se produzcan daños al sistema de enfriamiento debidos a ciclos cortos Este termóstato incluye un retardo automático de cinco minutos después de desconectar el sistema de enfriamiento para proteger al compresor Esta función de protección también está presente mientras la unidad está funcionando con aplicaciones de calefacción Notas Importantes Si la unidad pierde potencia o s...

Page 7: ...el software apaga la unidad inmediatamente si la temperatura de la habitación es superior a 93 F 34 C Si la temperatura sube por encima de 99 F 37 C el termostato apaga la unidad MEMORIA NO VOLÁTIL En caso de un apagón la función de memoria no volátil de esta unidad permite recuperar todos los ajustes Cuando se reponga la potencia de CA después de un apagón todos los ajustes se recuperan de la mem...

Page 8: ...tes internos Filtro de vacío hasta 3 veces y reutilizaciones Nota Los dos filtros usados para la unidad son el mismo tipo pero diversos tamaños Sea seguro que el tamaño apropiado está instalado MANTENIMIENTO MENSUAL 1 Inspección exterior Inspeccione los componentes exteriores y asegúrese de que están instalados correctamente Observe cualquier ruido anormal de la unidad Para más información sobre p...

Page 9: ...eil sur une surface stable et plane Ne pas lâcher ni jeter l appareil et ne pas le placer sur une surface pouvant entraîner sa chute Les mauvais traitements peuvent endommager l appareil et créer des conditions dangereuses ou invalider la garantie Inspecter le cordon d alimentation avant d utiliser l appareil Ne pas utiliser l appareil si le cordon est endommagé Le remplacer par un cordon de type ...

Page 10: ...mprend un dispositif automatique de protection du compresseur pour éviter tout risque d endommagement du système de refroidissement par cycle court Ce thermostat entraîne automatiquement un retard de cinq minutes après arrêt du système de refroidissement pour protéger le compresseur Cette protection est également présente lorsque l appareil est utilisé pour le chauffage Notes Importantes Si l appa...

Page 11: ... SECURITE EN CAS DE HAUSSE DE TEMPERATURE Lorsque le sélecteur est sur HEAT une fonction logicielle éteint automatiquement l appareil si la température ambiante monte au dessus de 34 C Si la température monte au dessus de 37 C le thermostat éteint mécaniquement l appareil MEMOIRE NON VOLATILE En cas de panne de courant la fonction de mémoire non volatile de cet appareil permet le rétablissement de...

Page 12: ...filtre 3M HAF propre Utilisez les filtres propres de 3M HAF de subsistance propre de filtres dans l unité à tout moment pour garder hors de la poussière et pour protéger les composants internes Filtre à vide jusqu à 3 fois et réutilisations Remarque Les deux filtres utilisés pour l unité sont le même type mais différentes tailles Soyez sûr que la taille appropriée est installée ENTRETIEN MENSUEL 1...

Reviews: