background image

 

07-01583B  06-07  Copyright 2007 Dri-Eaz Products, Inc. 

 

injury. Always place a strap around the top of the EB1400 
and secure it to the Unimover or hand truck before 
attempting to lift the unit.  

 

3.  Store with left side of unit against the wall and keep 

upright while transporting. Secure into place with a strap. 

NOTICE!

 Store securely to avoid any damaging impact to 

internal parts. 

 

MAINTENANCE 

WARNING! 

Turn off and unplug unit before cleaning or 

servicing. 

B

EFORE 

E

ACH 

U

SE

 

1. 

Inspect Power Cord

 

 

Inspect power cord for cuts, fraying or damage; do not use 
if damaged.  

W

EEKLY 

M

AINTENANCE

 

Inspect Front Filter 

Slide duct ring adapters for outlet D off to remove front filter for 
cleaning.  Slide out the filter and inspect for damage or 
excessive dirt. Use a clean 3M™ HAF Filter (below). Replace 
filter every four months or earlier if necessary. For Parts and 
Service call your local distributor, or the Dri-Eaz Service 
Department at 800-932-3030 or (360) 757-7776. 

Use Clean 3M HAF Filters 

Keep clean filters in the unit at all times to keep out dust and 
protect internal components. Vacuum filter up to 3 times and 
reuse. 

Note:

 The two filters used for the unit are the same type 

but different sizes. Be sure the appropriate size is installed. 

M

ONTHLY 

M

AINTENANCE

 

1. 

Exterior Inspection

  

Inspect exterior components and make sure they are 
properly installed. Listen to the unit for abnormal sounds. 
For Parts and Service call your local distributor, or the  
Dri-Eaz Service Department at 800-932-3030 or (360) 
757-7776. 

2. 

Clean Exterior

  

Clean the housing with a damp cloth. Bring back the 
original shine with a vinyl cleaner/polish like those used on 
automobile plastics. 

3. 

Inspect Back Filters 

The second  set of filters is in the back of the unit on the 
condenser side and may only require cleaning periodically 
(every 3-6 months depending on the cleanliness of the air 
ducted or drawn into the condenser inlet). To access these 
filters, use a 3/8” socket wrench to remove the 6 ¼-20 
bolts holding the back cover in place. If you need further 
assistance, contact the Dri-Eaz Service Department at 
800-932-3030 or (360) 757-7776.

 

 

 

 

 

 

 

 

 

 

 

 
 

                       Condenser Side Filter Location

 

 

SPECIFICATIONS 

Model F374 
Weight 

185 lbs. (84.1 kg)   

Dimensions (HxDxW) 

45" x 25" x 31"  
(114.3 cm x 63.5 cm x 78.7 
cm)

 

Amperage 11.7 

amps 

BTU’s (cooling capacity) 

10,120 BTU/h 

CFM 

470 Evaporator air stream 
750 Condenser air stream 

Power 

1265 W (1.695 HP) 

Filters 

3M HAF Filter 

Cord Length 

20 ft. (6.1 m) 

Construction 

Rotomolded shell 

Safety 

ETL listed to UL 474 and 
CSA C22.2 #92-1971 

 

Specifications are subject to change without notice. 

Some values may be approximate.

  

FOR PARTS AND SERVICE CALL YOUR LOCAL DISTRIBUTOR,  

or the Dri-Eaz Service Department at 800-932-3030 or (360)  
757-7776. 

www.dri-eaz.com

 

 

 

Back filters 

Summary of Contents for EB1400

Page 1: ...r place where it could fall Rough treatment can damage the unit and may create a hazardous condition or void the warranty Inspect the power cord before use If cord is damaged do not use Replace with a cord of the same type and amperage rating Protect cord from damage by turning off unit before unplugging Always grasp the plug not pulling on the cord to unplug The unit is designed to operate on a 1...

Page 2: ...the cooling system from short cycling This thermostat automatically provides a 5 minute delay after turning off the cooling system output to protect the compressor This protection is also present while operating the unit in heating applications Important Notes If unit loses power or gets unplugged during operation operator MUST wait 5 minutes before plugging unit back in or risk damaging the compr...

Page 3: ... above 93 F 34 C If the temperature rises above 99 F 37 C the thermostat mechanically turns the unit off NON VOLATILE MEMORY In the event of a power failure the non volatile memory feature of this unit allows all settings to be recovered When AC power is restored after an outage all settings are retrieved from memory and reinstated RESETTING THERMOSTAT The Reset feature allows the user to complete...

Page 4: ...ction Inspect exterior components and make sure they are properly installed Listen to the unit for abnormal sounds For Parts and Service call your local distributor or the Dri Eaz Service Department at 800 932 3030 or 360 757 7776 2 Clean Exterior Clean the housing with a damp cloth Bring back the original shine with a vinyl cleaner polish like those used on automobile plastics 3 Inspect Back Filt...

Page 5: ...a unidad siempre sobre una superficie estable y nivelada No la deje caer la tire ni la coloque en un lugar donde pueda caerse La manipulación brusca puede dañar la unidad y dar lugar a una situación peligrosa o invalidar la garantía Inspeccione el cable de alimentación antes de usar Si el cable está dañado no lo use Cámbielo por un cable del mismo tipo y amperaje nominal Proteja el cable de los da...

Page 6: ...presor para evitar que se produzcan daños al sistema de enfriamiento debidos a ciclos cortos Este termóstato incluye un retardo automático de cinco minutos después de desconectar el sistema de enfriamiento para proteger al compresor Esta función de protección también está presente mientras la unidad está funcionando con aplicaciones de calefacción Notas Importantes Si la unidad pierde potencia o s...

Page 7: ...el software apaga la unidad inmediatamente si la temperatura de la habitación es superior a 93 F 34 C Si la temperatura sube por encima de 99 F 37 C el termostato apaga la unidad MEMORIA NO VOLÁTIL En caso de un apagón la función de memoria no volátil de esta unidad permite recuperar todos los ajustes Cuando se reponga la potencia de CA después de un apagón todos los ajustes se recuperan de la mem...

Page 8: ...tes internos Filtro de vacío hasta 3 veces y reutilizaciones Nota Los dos filtros usados para la unidad son el mismo tipo pero diversos tamaños Sea seguro que el tamaño apropiado está instalado MANTENIMIENTO MENSUAL 1 Inspección exterior Inspeccione los componentes exteriores y asegúrese de que están instalados correctamente Observe cualquier ruido anormal de la unidad Para más información sobre p...

Page 9: ...eil sur une surface stable et plane Ne pas lâcher ni jeter l appareil et ne pas le placer sur une surface pouvant entraîner sa chute Les mauvais traitements peuvent endommager l appareil et créer des conditions dangereuses ou invalider la garantie Inspecter le cordon d alimentation avant d utiliser l appareil Ne pas utiliser l appareil si le cordon est endommagé Le remplacer par un cordon de type ...

Page 10: ...mprend un dispositif automatique de protection du compresseur pour éviter tout risque d endommagement du système de refroidissement par cycle court Ce thermostat entraîne automatiquement un retard de cinq minutes après arrêt du système de refroidissement pour protéger le compresseur Cette protection est également présente lorsque l appareil est utilisé pour le chauffage Notes Importantes Si l appa...

Page 11: ... SECURITE EN CAS DE HAUSSE DE TEMPERATURE Lorsque le sélecteur est sur HEAT une fonction logicielle éteint automatiquement l appareil si la température ambiante monte au dessus de 34 C Si la température monte au dessus de 37 C le thermostat éteint mécaniquement l appareil MEMOIRE NON VOLATILE En cas de panne de courant la fonction de mémoire non volatile de cet appareil permet le rétablissement de...

Page 12: ...filtre 3M HAF propre Utilisez les filtres propres de 3M HAF de subsistance propre de filtres dans l unité à tout moment pour garder hors de la poussière et pour protéger les composants internes Filtre à vide jusqu à 3 fois et réutilisations Remarque Les deux filtres utilisés pour l unité sont le même type mais différentes tailles Soyez sûr que la taille appropriée est installée ENTRETIEN MENSUEL 1...

Reviews: