Dri-Eaz EB1400 Owner'S Manual Download Page 2

 

07-01583B  06-07  Copyright 2007 Dri-Eaz Products, Inc. 

 

Duct A 
(Heat 
inlet back 
of unit) 

PARTS IDENTIFICATION 

(Shown, below)

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

Front and Right Side View

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Back and Left Side View 

 
 
 
 
 
 

OPERATING INSTRUCTIONS 

G

ETTING 

S

TARTED

 

 

P

LACEMENT

:

 

For cooling or heating, place at least one EB1400 per room. 

1.  Place the unit on a level surface.  

2.  Make sure the System switch is set to Off then plug power 

cord into a standard 115v grounded outlet. 

3.  Set the digital temperature controls needed to function 

(see below).  

4.  Check for proper operation before leaving the unit 

unattended. Do not move or carry the EB1400 when it is 
running or plugged in. 

O

PERATING 

R

ANGE

 

Recommended operating range is between 60° – 115° F.   
The EB 1400 will not function properly when operating in 
environment with temperatures outside this range. 

C

YCLE 

T

IMES AND 

C

OMPRESSOR 

P

ROTECTION

 

The EB1400 thermostat includes an automatic compressor 
protection feature to avoid potential damage to the cooling 
system from short cycling. This thermostat automatically 
provides a 5-minute delay after turning off the cooling system 
output to protect the compressor. This protection is also 
present while operating the unit in heating applications. 

Important Notes:  

 

If unit loses power or gets unplugged during 
operation, operator MUST wait 5 minutes before 
plugging unit back in or risk damaging the compressor 
or tripping the circuit breaker in the facility.  

 

Always turn the System switch to OFF before 
unplugging.  

 

If the System setting is adjusted during operation the 
unit will automatically delay 5 minutes before start-up.  

 

When switching unit from cooling to heating or 
heating to cooling operator must adjust setpoint 
temperature.  

 

T

ESTING AND 

P

ROGRAMMING 

T

HERMOSTAT

 

D

IGITAL 

C

ONTROLS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Left side 

Duct D 
(Cold outlet) 

Front filter 
(Inlet) 

Drain Hose 
pocket 

Wheel casters 

Rotomolded 
shell

Right 
side 

Back housing 
(filter set located 
inside)  

   Condenser

Duct B  
(Heat 
outlet) 

Touchpad 
temperature 
controls 

Cord 
pocket 

Left side

Touchpad 
temperature 
controls 

Wheel casters 

Rotomolded 
shell

Heat 

Cool 

Off 

Up 

Down 

Reset 

On 

Auto 

Fan 

Digital screen 

Summary of Contents for EB1400

Page 1: ...r place where it could fall Rough treatment can damage the unit and may create a hazardous condition or void the warranty Inspect the power cord before use If cord is damaged do not use Replace with a cord of the same type and amperage rating Protect cord from damage by turning off unit before unplugging Always grasp the plug not pulling on the cord to unplug The unit is designed to operate on a 1...

Page 2: ...the cooling system from short cycling This thermostat automatically provides a 5 minute delay after turning off the cooling system output to protect the compressor This protection is also present while operating the unit in heating applications Important Notes If unit loses power or gets unplugged during operation operator MUST wait 5 minutes before plugging unit back in or risk damaging the compr...

Page 3: ... above 93 F 34 C If the temperature rises above 99 F 37 C the thermostat mechanically turns the unit off NON VOLATILE MEMORY In the event of a power failure the non volatile memory feature of this unit allows all settings to be recovered When AC power is restored after an outage all settings are retrieved from memory and reinstated RESETTING THERMOSTAT The Reset feature allows the user to complete...

Page 4: ...ction Inspect exterior components and make sure they are properly installed Listen to the unit for abnormal sounds For Parts and Service call your local distributor or the Dri Eaz Service Department at 800 932 3030 or 360 757 7776 2 Clean Exterior Clean the housing with a damp cloth Bring back the original shine with a vinyl cleaner polish like those used on automobile plastics 3 Inspect Back Filt...

Page 5: ...a unidad siempre sobre una superficie estable y nivelada No la deje caer la tire ni la coloque en un lugar donde pueda caerse La manipulación brusca puede dañar la unidad y dar lugar a una situación peligrosa o invalidar la garantía Inspeccione el cable de alimentación antes de usar Si el cable está dañado no lo use Cámbielo por un cable del mismo tipo y amperaje nominal Proteja el cable de los da...

Page 6: ...presor para evitar que se produzcan daños al sistema de enfriamiento debidos a ciclos cortos Este termóstato incluye un retardo automático de cinco minutos después de desconectar el sistema de enfriamiento para proteger al compresor Esta función de protección también está presente mientras la unidad está funcionando con aplicaciones de calefacción Notas Importantes Si la unidad pierde potencia o s...

Page 7: ...el software apaga la unidad inmediatamente si la temperatura de la habitación es superior a 93 F 34 C Si la temperatura sube por encima de 99 F 37 C el termostato apaga la unidad MEMORIA NO VOLÁTIL En caso de un apagón la función de memoria no volátil de esta unidad permite recuperar todos los ajustes Cuando se reponga la potencia de CA después de un apagón todos los ajustes se recuperan de la mem...

Page 8: ...tes internos Filtro de vacío hasta 3 veces y reutilizaciones Nota Los dos filtros usados para la unidad son el mismo tipo pero diversos tamaños Sea seguro que el tamaño apropiado está instalado MANTENIMIENTO MENSUAL 1 Inspección exterior Inspeccione los componentes exteriores y asegúrese de que están instalados correctamente Observe cualquier ruido anormal de la unidad Para más información sobre p...

Page 9: ...eil sur une surface stable et plane Ne pas lâcher ni jeter l appareil et ne pas le placer sur une surface pouvant entraîner sa chute Les mauvais traitements peuvent endommager l appareil et créer des conditions dangereuses ou invalider la garantie Inspecter le cordon d alimentation avant d utiliser l appareil Ne pas utiliser l appareil si le cordon est endommagé Le remplacer par un cordon de type ...

Page 10: ...mprend un dispositif automatique de protection du compresseur pour éviter tout risque d endommagement du système de refroidissement par cycle court Ce thermostat entraîne automatiquement un retard de cinq minutes après arrêt du système de refroidissement pour protéger le compresseur Cette protection est également présente lorsque l appareil est utilisé pour le chauffage Notes Importantes Si l appa...

Page 11: ... SECURITE EN CAS DE HAUSSE DE TEMPERATURE Lorsque le sélecteur est sur HEAT une fonction logicielle éteint automatiquement l appareil si la température ambiante monte au dessus de 34 C Si la température monte au dessus de 37 C le thermostat éteint mécaniquement l appareil MEMOIRE NON VOLATILE En cas de panne de courant la fonction de mémoire non volatile de cet appareil permet le rétablissement de...

Page 12: ...filtre 3M HAF propre Utilisez les filtres propres de 3M HAF de subsistance propre de filtres dans l unité à tout moment pour garder hors de la poussière et pour protéger les composants internes Filtre à vide jusqu à 3 fois et réutilisations Remarque Les deux filtres utilisés pour l unité sont le même type mais différentes tailles Soyez sûr que la taille appropriée est installée ENTRETIEN MENSUEL 1...

Reviews: