background image

Operating the Dragon

inspecting before operation

WARNING! Before starting the Dragon:

• Check for any fuel leaks around the fuel tank or fuel

li nes.

• Check for nearby hazards like combustible materials

or flammable vapor sources.

• Check the power cord for damage.

Correct these and any other safety hazards before
starting the Dragon.

Starting the Dragon

t Check the fuel tank. If needed, add diesel fuel to the

fuel tank. Do not overfill. See 'Fuel Type." p. 2, for

recommended fuels.

2. With the ducting secured. plug in the power cord into

a suitable outlet

3. Turn the CONTROL KNOB (Fig. 1, C)) to the "manual"

position.

4. If you wish to use the Dragon in thermostat mode,

place the thermostat sensor in the target area, and
select "Thermostat" with the CONTROL KNOB.

CAUTION. Monitor the settings on the Dragon and
conditions in the structure at least once a day during
operation.

Controlling the 

temperature

111^1

The Dragon is equipped with a remote thermostat that
can be used to control the temperature in the target
area. To use the Dragon in thermostat mode, set the
desired temperature on the thermostat control and place
the control in the target area.

The Dragon may operated without the thermostat by
selecting "Manual" with the CONTROL KNOB.

Shutting the Dragon Off

Turn the CONTROL KNOB to the "Off' position.

CAUTION: Do not unplug the unit or otherwise turn off
the power until the fan stops operating. Failure to let the

unit complete the cooling cycle could damage the heat

exchanger and will not be covered under warranty.

Special Instructions

Bleeding the fuel line

In certain circumstances air may accumulate in the fuel
li ne and prevent proper operation. To remove air from

the fuel line. follow these steps:

Supplies needed: Yi in. i.d. 

6 ft. clear plastic hose.

receptacle for fuel, rags or cloths to clean up any spills.

wrenches and screwdriver,

1. Turn the CONTROL KNOB to the 'Off position.

2. Open hood. Be sure to secure it with the retention

cable provided,

3, Loosen (but do not remove) purge valve with a

wrench. Attach a clear plastic hose over the purcge

valve and place the end in a suitable receptacle on
the ground.

4. Turn CONTROL KNOB to the "Manual" position. The

fuel pump will run for approximately 20 seconds, and

a mixture of fuel and air will flow through the plastic

tube.

5. Press BURNER RESET BUTTON (Fig. 1, G) to

repeat the purge process. Repeat until the fuel flows
free of air bubbles.

6. Remove plastic hose and retighten bleed valve.
7. Close hood. The Dragon may now be operated

normally.

Adjusting for Altitude

The combustion air intake control for the furnace is
factory set for operation at altitudes ranging from sea
level up to 5000 ft. (1500m). To assure proper operation
and maximum performance at higher altitudes, t is

necessary to adjust the combustion air/fuel mixture.

The best guide to proper air/fuel mixture is exhaust

color. The Dragon exhaust should always be clear.
Black or white smoke indicates an improper air/fuel
mixture:

a) If the exhaust is clear, no adjustment is needed,
b) If the smoke is dark or black, there is not enough
air in the mixture.
c) If the smoke is white, there is too much air and not

enough fuel in the mixture. or there is water in the fuel

If the smoke color is either black or white,  follow

these steps to adjust the air/fuel ratio.

a) A 

higher 

number 

corrects for black smoke 

(allows

more air into the combustion chamber);
b) A 

lower 

number 

corrects for white smoke 

(allows

less air).

9

Air Marketing Group (.LC

141 

Kinclerkarnack 

Rd. Park Ridge, NJ 07656 Tel 201-782-1782 Fax. 201-782-1783 Web www amgair 

corn 

Email: info@amgair 

corn

Summary of Contents for Dragon X2 F429

Page 1: ...st for altitude changes could cause injury permanent damage to the unit and secondary damage when ducting into a structure It may also void the Dri Eaz warranty Refer to Adjusting for Altitude p 4 for...

Page 2: ...e Dragon may be operated with higher percentages of kerosene up to 100 kerosene but this requires special adjustments Contact Dri Eaz Service at 800 932 3030 for instructions For use in water damage r...

Page 3: ..._ _ r _ 7 a 7 7 2 _ 11 _ 1 _ 1 1 1 _ _ 1 _ _ _ _ man 1 1 w m _ _ _ _ 1 _ _ Tr _ El r ar r 2 _ _ 1 7 n _ _...

Page 4: ...ine follow these steps Supplies needed Yi in i d x 6 ft clear plastic hose receptacle for fuel rags or cloths to clean up any spills wrenches and screwdriver 1 Turn the CONTROL KNOB to the Off positio...

Page 5: ...uel If the Dragon runs out of fuel a fuel cutoff sensor will automatically shut the heater off and the BURNER CONTROL BUTTON Fig 1 G will glow red The fan may continue to cycle on and off until coolin...

Page 6: ...peration these components should be inspected once a year and cleaned if necessary by a qualified HVAC technician Contact your local distributor or the Dri Eaz Service Department at 800 932 3030 for t...

Page 7: ...culaciOn de aire alrededor de la unidad para clue la combustiOn sea adecuada Mantenge todos los elementos infiamables lejos del calentador Hap tareas de reparacion y mantenimiento unicamente cuando el...

Page 8: ...danos causados par el ague y secar construcciones nuevas el Dragon puede aumentar la eficacia de secado El calor que aporta el Dragon aumentara el indice de evaporacien al disminuir la humedad relati...

Page 9: ...nolque de su vehiculo Para evitar movimientos inesperados asi como posibles Janos y lesiones coloque sienripre tacos en las ruedas cuando estacione el rernolque Antes de cada viaje realice un control...

Page 10: ...ra que haya en la estructura per ejemplo la ventana de un sotano o el bloque de ventilacion de un entresuelo Dada que cada estructura es Unica por le general tendra que crear un adaptador que se adecu...

Page 11: ...ara funcionar en alturas que van desde el nivel del mar haste los 5000 pies 1500 m Para garantizar el correcto funcionamiento y el maxima rendimiento en lugares de gran altura es necesario ajustar la...

Page 12: ...e y se detenga en forma internnitente haste que termine de enfriarse Siga estas instrucciones pare reiniciar la unidad Consejo Puede ser necesario repetir este operacian ties o cuatro veces haste que...

Page 13: ...linea de combustible en la pagina 11 3 Mantenimiento del quemador Junto con la documentacien sabre el Dragon se incluyen copias del AFIAFG Oil Burner Manual Manual del quemador de fueloleo modelo AF A...

Page 14: ...bustible indice de consumo de combustible 0 8 gaVh I 3 1 h PresiOn de la bombe de combustible 1 40 lb n2 I 966 kPa Segundad Certificacion de ETL conforme a CSA S140 8 1967 Reaffirmed 2001 Portable Ind...

Page 15: ...du generateur La circulation d air autour de l apparell doit favoriser une bonne combustion Garder eloignees du generateur toutes les matieres inflammables Avant toute reparation cu tout entretien tai...

Page 16: ...geant un chauffage temporaire sec et propre Le Dragon favorise on sechage plus efficace lors dune refection dommages causes par l eau ou dun nouveau travail du batiment En effet la chaleur d appoint d...

Page 17: ...referer aux normes CSA B139 et CSA B140 1962 Avitaillement Le Dragon est livre avec un reservoir de carburant vide Faire le plein avant la mise en service de diesel ou de fuel oil lourd n 1 ou n 2 Par...

Page 18: ...eur de ce dernier clans la zone cible puis mettre le BOUTON DE COMMANDE sur Thermostat MISE EN GARDE Verifier les A reglages du Dragon et les conditions dans la structure au moms une fois par Jour de...

Page 19: ...ee blanche en revanche ternoigne dun m lange pauvre exces d air ou de la presence d eau dans le carburant Suivre les tapes suivantes de reglage du m lange lorsque la fumee est blanche ou noire a Un ch...

Page 20: ...ieurs tentatives contacter le service technique de Dri Eaz au 800 932 3030 AVIS Le Dragon doit faire I objet dun examen visuel au moms une fois par jour de fonctionnement Regarder s il n y a pas de fu...

Page 21: ...r et 8 po de diametre 7 6 m x 20 cm Une extrennite de _ chaque game est munie Tune manchette cousue avec ceinture et boucle integrees 1 thermostat avec cordon de capteur de 60 pi 18 3 m 1 Guide d util...

Page 22: ...na 23 la explicacion de los simbolos utilizados en el esquema Voir tegende du schema p 23 1 4 51 V 111 3 iv a f X4KINI i l l Ch I T Air Marketing Group LW 141 Kinclerkarnack Rd Park Ridge NJ 07656 Tel...

Page 23: ...3 SJT FAISCEAU DE CABLES 241 AC 24VAC 24 V c a BLOWER VENTILADOR SOUFFLANTE BULB BOMBILLA AMPOULE BURNER QUEMADOR BRCJLEUR BURNER CONTROL SVVITCH 1ADJUST TO 155 F INTERRUPTOR DE CONTROL DEL QUEMADOR L...

Reviews: