OVERVIEW

Introduction

The Dragon X2 Mobile Furnace is an indirect fired

heater. This design keeps combustion air separate from
heated air and allows the Dragon to heat air without

adding any moisture fumes or smoke.

The Dragon should always be operated outdoors, and

should utilize outside air for combustion. An electric fan
directs this heated air into the structure through ducting.
The remote thermostat automatically cycles the Dragon
on and off to maintain a preset temperature in the target
area.

Principles of Use
The clean, dry heat from the Dragon helps reduce drying
times while maintaining stable and comfortable
temperatures. The Dragon is ideal for wide range of
applications, including

• water damage restoration
• new construction drying
• unheated jobsites
• temporary event shelters
• workshops. storage rooms, and warehouses
• greenhouses and polyurethane tunnels for

agriculture

• any situation calling for clean, dry temporary neat.

Fuel type

The Dragon X2 Mobile Furnace can operate for approxi-

mately 72 hours on a single tank, depending on

conditions.The Dragon is designed to operate on no. 1
or no. 2 diesel or fuel oil. In cold weather, you may add

kerosene to the diesel as described under "Cold

temperature recommendations," below.

WARNING: Failure to use diesel fuel or a diesel-
kerosene mixture as specified could cause injury
and permanent damage to the unit. It may also void
the Dri-Eaz warranty.

For best results. purchase fresh fuel from a reliable fuel

oil distributor. Keep the Dragon fuel tank full to help

prevent the formation of condensation inside the tank.

When not using the Dragon for extended periods of time,
consider the addition of a diesel fuel stabilizer to the fuel,
available at most automobile parts stores.

Cold temperature recommendations

In temperatures below 23

v

F (-5"C), diesel tends to

thicken and may block the fuel filters. To improve fuel
flow characteristics in cold temperatures, a mixture
containing up to 15% kerosene may be used. The

Dragon may be operated with higher percentages of

kerosene up to 100% kerosene, but this requires special

adjustments. Contact Dri-Eaz Service at 800-932-3030
for instructions.

For use in water damage restoration and new

construction drying, the Dragon can increase drying
efficiency. The added heat from the Dragon will increase
the rate of evaporation by decreasing the relative

humidity of the affected area. Raising the temperature of

a drying area with the Dragon from 60'' to 70'F can

increase the evaporative potential of your existing drying

system up to 45 percent.

For best results when using the Dragon for restoration,

you should understand the basic principles of structural
drying. You can learn these skills and more in an IICRC-
certified Applied Structural Drying (ASD) course. To

learn more about ASD courses, contact the Dri-Eaz
Education Department at 800-932-3030.

Electrical requirements

The Dragon X2 Mobile Furnace is designed to
operate on a 115V/60 Hz electrical connection. The unit

requires 10 amps. Make sure that the electrical outlet is

grounded with three prongs. When using with an
extension cord, use only 

grounded cord intended for

outdoor use and rated to deliver enough power to the

Dragon.

Trailer Safety

Do not exceed the rated towing or tongue weight

capacity of your vehicle. To prevent unexpected

movement and possible damage and injury, always

chock the wheels securely when parking the trailer.

Perform a trailer safety inspection before each trip. Make

sure that

• The ball mount is properly inserted 

i

nto the receiver

and the safety pin installed.

• The hitch coupler is locked in place and the safety

pin is installed.

• Safety chains are properly attached.
• The electrical plug is properly installed.
• Trailer tires are properly inflated.

To adjust for proper combustion and for use at high
altitudes, see 
"Adjusting for Altitude," p. 4.

OPERATING THE DRAGON

Setting up the Dragon

Choosing a location

WARNING! Use the Dragon outdoors only. Place the
unit on a level, stable surface. Be sure to chock the

Air Marketing Group (,LC

141 

Kinclerkarnack 

Rd. Park Ridge, NJ 07656 Tel 201-782-

11782

 Fax. 201-782-1783 Web www amgair corn Email: info@amgair 

corn

Summary of Contents for Dragon X2 F429

Page 1: ...st for altitude changes could cause injury permanent damage to the unit and secondary damage when ducting into a structure It may also void the Dri Eaz warranty Refer to Adjusting for Altitude p 4 for...

Page 2: ...e Dragon may be operated with higher percentages of kerosene up to 100 kerosene but this requires special adjustments Contact Dri Eaz Service at 800 932 3030 for instructions For use in water damage r...

Page 3: ..._ _ r _ 7 a 7 7 2 _ 11 _ 1 _ 1 1 1 _ _ 1 _ _ _ _ man 1 1 w m _ _ _ _ 1 _ _ Tr _ El r ar r 2 _ _ 1 7 n _ _...

Page 4: ...ine follow these steps Supplies needed Yi in i d x 6 ft clear plastic hose receptacle for fuel rags or cloths to clean up any spills wrenches and screwdriver 1 Turn the CONTROL KNOB to the Off positio...

Page 5: ...uel If the Dragon runs out of fuel a fuel cutoff sensor will automatically shut the heater off and the BURNER CONTROL BUTTON Fig 1 G will glow red The fan may continue to cycle on and off until coolin...

Page 6: ...peration these components should be inspected once a year and cleaned if necessary by a qualified HVAC technician Contact your local distributor or the Dri Eaz Service Department at 800 932 3030 for t...

Page 7: ...culaciOn de aire alrededor de la unidad para clue la combustiOn sea adecuada Mantenge todos los elementos infiamables lejos del calentador Hap tareas de reparacion y mantenimiento unicamente cuando el...

Page 8: ...danos causados par el ague y secar construcciones nuevas el Dragon puede aumentar la eficacia de secado El calor que aporta el Dragon aumentara el indice de evaporacien al disminuir la humedad relati...

Page 9: ...nolque de su vehiculo Para evitar movimientos inesperados asi como posibles Janos y lesiones coloque sienripre tacos en las ruedas cuando estacione el rernolque Antes de cada viaje realice un control...

Page 10: ...ra que haya en la estructura per ejemplo la ventana de un sotano o el bloque de ventilacion de un entresuelo Dada que cada estructura es Unica por le general tendra que crear un adaptador que se adecu...

Page 11: ...ara funcionar en alturas que van desde el nivel del mar haste los 5000 pies 1500 m Para garantizar el correcto funcionamiento y el maxima rendimiento en lugares de gran altura es necesario ajustar la...

Page 12: ...e y se detenga en forma internnitente haste que termine de enfriarse Siga estas instrucciones pare reiniciar la unidad Consejo Puede ser necesario repetir este operacian ties o cuatro veces haste que...

Page 13: ...linea de combustible en la pagina 11 3 Mantenimiento del quemador Junto con la documentacien sabre el Dragon se incluyen copias del AFIAFG Oil Burner Manual Manual del quemador de fueloleo modelo AF A...

Page 14: ...bustible indice de consumo de combustible 0 8 gaVh I 3 1 h PresiOn de la bombe de combustible 1 40 lb n2 I 966 kPa Segundad Certificacion de ETL conforme a CSA S140 8 1967 Reaffirmed 2001 Portable Ind...

Page 15: ...du generateur La circulation d air autour de l apparell doit favoriser une bonne combustion Garder eloignees du generateur toutes les matieres inflammables Avant toute reparation cu tout entretien tai...

Page 16: ...geant un chauffage temporaire sec et propre Le Dragon favorise on sechage plus efficace lors dune refection dommages causes par l eau ou dun nouveau travail du batiment En effet la chaleur d appoint d...

Page 17: ...referer aux normes CSA B139 et CSA B140 1962 Avitaillement Le Dragon est livre avec un reservoir de carburant vide Faire le plein avant la mise en service de diesel ou de fuel oil lourd n 1 ou n 2 Par...

Page 18: ...eur de ce dernier clans la zone cible puis mettre le BOUTON DE COMMANDE sur Thermostat MISE EN GARDE Verifier les A reglages du Dragon et les conditions dans la structure au moms une fois par Jour de...

Page 19: ...ee blanche en revanche ternoigne dun m lange pauvre exces d air ou de la presence d eau dans le carburant Suivre les tapes suivantes de reglage du m lange lorsque la fumee est blanche ou noire a Un ch...

Page 20: ...ieurs tentatives contacter le service technique de Dri Eaz au 800 932 3030 AVIS Le Dragon doit faire I objet dun examen visuel au moms une fois par jour de fonctionnement Regarder s il n y a pas de fu...

Page 21: ...r et 8 po de diametre 7 6 m x 20 cm Une extrennite de _ chaque game est munie Tune manchette cousue avec ceinture et boucle integrees 1 thermostat avec cordon de capteur de 60 pi 18 3 m 1 Guide d util...

Page 22: ...na 23 la explicacion de los simbolos utilizados en el esquema Voir tegende du schema p 23 1 4 51 V 111 3 iv a f X4KINI i l l Ch I T Air Marketing Group LW 141 Kinclerkarnack Rd Park Ridge NJ 07656 Tel...

Page 23: ...3 SJT FAISCEAU DE CABLES 241 AC 24VAC 24 V c a BLOWER VENTILADOR SOUFFLANTE BULB BOMBILLA AMPOULE BURNER QUEMADOR BRCJLEUR BURNER CONTROL SVVITCH 1ADJUST TO 155 F INTERRUPTOR DE CONTROL DEL QUEMADOR L...