Instructions for use

  |  

LAR 8000

  

39

Description

  |  

en

3.1.2 Rear 

view

3.2 Functional 

description

3.2.1 

Oxygen operation mode feature description

In oxygen operation mode, the rebreather works with a closed breathing circuit 
which means the diver breathes almost exclusively pure oxygen.

45287

1

Exhalation bag

6

Oxygen cylinder

2

CO

2

 absorber

7

Strap

3

CO

2

 absorber strap

8

Pressure reducer

4

Rotary switch

9

Inhalation bag

5

Switch device

10 Protective cover

1

2
3

4

6

5

9

10

8

7

B

Summary of Contents for LAR 8000

Page 1: ...LAR 8000 Instructions for use de enUS...

Page 2: ...de Gebrauchsanweisung 3 enUS Instructions for use 35 LAR 8000...

Page 3: ...renzende Eigenschaften 11 4 Vorbereitungen f r den Einsatz 12 4 1 Sauerstoffbetrieb vorbereiten 12 4 1 1 Sauerstoffflasche montieren 12 4 1 2 Flaschendruck und Gasversorgung pr fen 12 4 2 Mischgasbetr...

Page 4: ...eren und instand halten Dr ger empfiehlt einen Service Vertrag mit Dr ger abzuschlie en und alle Instandhaltungsarbeiten durch Dr ger durchf hren zu lassen F r Instandhaltungsarbeiten nur Original Dr...

Page 5: ...gnet ist und ob die richtige Dosierung eingestellt ist Brand und Explosionsgefahr durch Sauerstoff Sauerstoff kann eine Selbstentz ndung von l und Fett bewirken Dadurch kann ein Brand oder eine Explos...

Page 6: ...r ger eingetragen sind www draeger com trademarks 3 Beschreibung 3 1 Produkt bersicht 3 1 1 Frontansicht Marke Markeninhaber DiveSorb Dr ger 45245 1 Mundst ck 8 Untere Schnellverschl sse 2 Einatemschl...

Page 7: ...mit einem geschlossenen Atemkreislauf in dem der Taucher fast ausschlie lich reinen Sauerstoff atmet 5 Obere Schnellverschl sse 12 Ausatemschlauch 6 Hand Bypass 13 Kopfband 7 berdruckventil 45287 1 A...

Page 8: ...damit direkt von der k rperlichen Leistung des Tauchers ab 3 2 2 Funktionsschema Sauerstoffbetrieb Nach dem ffnen der Sauerstoffflasche str mt Sauerstoff ber den Druckminderer zum Umschaltblock nicht...

Page 9: ...O2 Absorbers absorbiert Aufgrund des halbgeschlossenen Kreislaufprinzips und der damit fest eingestellten Frischgasdosierungen ist der O2 Gehalt im Atemkreislauf praktisch immer geringer als der O2 Ge...

Page 10: ...kann das Ventil hat f nf Schaltstellungen Der Atemkreislauf im Ger t schlie t sich mit dem Gasstrom des gereinigten Gases vom CO2 Absorber zum Einatembeutel Falls erforderlich wird Frischgas durch den...

Page 11: ...osierung Bypass Benutzung durch schnelles Abtauchen und Sp lung des Atemkreislaufes bei Inbetriebnahme und Gaswechsel Gasverbrauch Sauerstoff Der Sauerstoffverbrauch ist abh ngig von Bypass Benutzung...

Page 12: ...nen 3 Sauerstoffflasche in die Flaschenmulde am unteren Ende des Geh uses hineinschieben 4 Flaschenventil an den Druckminderer anschrauben l und fettfrei halten Handanschluss kein Werkzeug verwenden 5...

Page 13: ...nschluss kein Werkzeug verwenden 3 Mitteldruckleitung der Mischgasflasche an den Mischgasanschluss anschlie en Bajonettkupplung 4 2 2 Mischgasdosierung pr fen 4 2 2 1 Pr fung der Dosierung vorbereiten...

Page 14: ...Dosierungspr fger t verwenden das f r das verwendete Nitrox Gemisch vorgesehen ist 1 Ventil der Mischgasflasche langsam ffnen 2 Drehschalter auf Mischbetrieb stellen Drehschalter ist senkrecht und im...

Page 15: ...r Mischgasflasche schlie en 7 Adapter vom Lungenautomaten l sen 4 2 2 4 Pr fung mit Pr fkoffer Voraussetzungen Kreislauftauchger t ist f r die Pr fung der Dosierung vorbereitet Arbeitsmittel Kreislauf...

Page 16: ...von 1 Vol vom angegebenen Wert liegen 4 3 CO2 Absorber vorbereiten 4 3 1 CO2 Absorber ausbauen 1 Schutzabdeckung an der Trageseite des Ger ts durch Aushaken der seitlichen Laschen entfernen 2 Spannba...

Page 17: ...en 6 Einwegpatrone einsetzen 7 CO2 Absorber mit Deckel fest schlie en und den Bajonettverschluss durch Drehen verriegeln 4 3 3 CO2 Absorber mit losem Atemkalk f llen Das Kreislauftauchger t ist nur f...

Page 18: ...Atemkalkbeh lters dr cken so dass ein Wandkontakt zwischen Manschette und Geh use gew hrleistet ist 6 CO2 Absorber bis zur F llmarke weiter f llen und verdichten 7 Dichtung am Deckelrand kontrollieren...

Page 19: ...ventil langsam ffnen 2 Mundst ckventil schlie en 3 berdruckventil gegen den Uhrzeigersinn bis zum Anschlag drehen Stellung Ge ffnet 4 Bypassventil auf Funktion pr fen dabei solange dr cken bis beide A...

Page 20: ...hlie en 2 Kreislauftauchger t vor die Brust halten 3 Obere und untere Schnellverschl sse des Kreislauftauchger ts in die Verschl sse des Tragesystems einrasten lassen Das Kreislauftauchger t soll stra...

Page 21: ...Wenn Wasser in das Kreislauftauchger t eindringt muss der Tauchgang umgehend abgebrochen werden HINWEIS Einkuppeln der Mischgaskupplung unter Wasser sollte vermieden werden Atembeutel auff llen Bypas...

Page 22: ...bsorber l sen und den CO2 Absorber leicht drehen so dass die Anschl sse an den Atembeuteln leichter zu l sen sind c Atembeutel 2 entfernen Dazu nacheinander die 3 gr nen Tasten dr cken und die Anschl...

Page 23: ...ach unten dr cken 2 Bajonettverschluss drehen und Deckel nach oben abnehmen 3 Atemkalk aussch tten oder Einwegpatrone entnehmen Beim Sch ttkalk auf die Gummimanschette achten 4 Atemkalk oder Einwegpat...

Page 24: ...urchf hren besonders Atembeutelmuffen und alle Gummiteile beachten X X Druckminderer Dichtring Hochdruckstut zen erneuern X2 2 Durch Dr ger bzw ausgebildetes Fachpersonal O Ringe und Steuerventile der...

Page 25: ...lie endem Wasser gr ndlich sp len 7 Alle Teile trocknen lassen Temperatur max 60 C Vor direkter Sonneneinstrahlung sch tzen 8 2 2 CO2 Absorber reinigen 1 Patrone Deckel und Manschette getrennt von den...

Page 26: ...kgasflaschenanschluss mit G 3 4 CGA 540 oder DIN M26x2 Gewinde f r Sauerstoffventile mit einem Nenndruck von 200 bar Flaschendruck 8 3 5 Lungenautomat Der Lungenautomat dient der geregelten Versorgung...

Page 27: ...en Geh useseite Der Drehschalter wird einerseits von der Sauerstoffflasche unter dem Kreislauftauchger t als auch von der separaten Mischgasflasche versorgt die ber eine Bajonettkupplung mit dem Misch...

Page 28: ...t Das Ventil ist mittels eines P Connectors am Ausatembeutel angeschlossen und durch einen roten O Ring markiert Au en hat das Ventil einen Verstell Hebel mit dem je nach Verwendung der Ansprechdruck...

Page 29: ...r im Geh use ein von der Innenseite werden sie mit einer berwurfmutter im Geh use verschraubt Die Verbindungsst cke sind farblich codiert auf der Ausatemseite finden sich rote Tasten und O Ringe und a...

Page 30: ...f ist zwischen dem Ein und Ausatembeutel der CO2 Absorber Am Ausatembeutel wird neben dem Gaseingang und dem CO2 Absorber auch das berdruckventil angeschlossen Am Einatembeutel wird der CO2 Absorber d...

Page 31: ...ich das Ventilmundst ck verschlie en Ein Kopfband dient der Sicherung des Mundst cks am Kopf des Tauchers Das Bei mundst ck stellt die Schnittstelle zum Taucher dar 8 4 Druckgasflaschen f llen In Anle...

Page 32: ...Entsorgung 11 Technische Daten 11 1 Kreislauftauchger t Dieses Produkt darf nicht als Siedlungsabfall entsorgt werden Es ist daher mit dem nebenstehenden Symbol gekennzeichnet Dr ger nimmt dieses Pro...

Page 33: ...ungenautomaten Tauchzeit Abh ngig vom Sauerstoffverbrauch Sauerstoffflasche 1 5 L T 80220 Stahl 200 bar G 3 4 115 mm ca 2 8 kg leer schwarz T V Sauerstoffflasche 2 L T 80222 Verbundmaterial NON Magnet...

Page 34: ...34 Gebrauchsanweisung LAR 8000 de Technische Daten Mischgasflasche 4 L T 16992 Verbundmaterial NON Magnetic Version in Anlehnung an STANAG 2897 class A 200 bar G 3 4 135 mm ca 4 5 kg leer schwarz T V...

Page 35: ...ime 43 4 Preparations for use 44 4 1 Preparing for oxygen operation mode 44 4 1 1 Mounting the oxygen cylinder 44 4 1 2 Checking cylinder pressure and gas supply 44 4 2 Preparing for mixed gas operati...

Page 36: ...e product Dr ger recommend a Dr ger service contract for all maintenance activities and that all repairs are carried out by Dr ger Use only genuine Dr ger spare parts and accessories Otherwise the pro...

Page 37: ...been set Fire and explosion hazard caused by oxygen Oxygen can cause spontaneous combustion of oil and grease This may result in a fire or explosion Keep the high pressure connectors plug in connectin...

Page 38: ...rademarks 3 Description 3 1 Product overview 3 1 1 Front view 45245 1 Mouthpiece 8 Lower quick release buckles 2 Inhalation hose 9 Pressure gauge 3 Mouthpiece closure 10 Connecting piece 4 Handle 11 L...

Page 39: ...n In oxygen operation mode the rebreather works with a closed breathing circuit which means the diver breathes almost exclusively pure oxygen 45287 1 Exhalation bag 6 Oxygen cylinder 2 CO2 absorber 7...

Page 40: ...ical exertion 3 2 2 Oxygen operation mode functional diagram After opening the oxygen cylinder oxygen flows through the pressure reducer to the switch device not for O2 version When the rotary switch...

Page 41: ...in the soda lime of the CO2 absorber Due to the semi closed circuit principle and the thus permanently set fresh gas dosages the O2 content in the breathing circuit is almost always lower than the O2...

Page 42: ...the relief valve The valve has five switching positions The breathing circuit in the device closes with the gas flow of the scrubbed gas from the CO2 absorber to the inhalation bag If necessary fresh...

Page 43: ...on dosage bypass use through rapid descent and flushing of the breathing circuit during start up and gas change Oxygen consumption Oxygen consumption depends on bypass use by flushing the breathing ci...

Page 44: ...kle 3 Push the oxygen cylinder into the cylinder recess at the bottom of the housing 4 Screw the cylinder valve onto the pressure reducer keep it free of oil and grease Manual connection do not use to...

Page 45: ...of oil and grease Manual connection do not use tools 3 Connect the medium pressure line of the mixed gas cylinder to the mixed gas connection bayonet coupling 4 2 2 Checking the mixed gas dosage 4 2 2...

Page 46: ...for the nitrox mixture in use 1 Slowly open the valve of the mixed gas cylinder 2 Set the rotary switch to mixed operation rotary switch is vertical and in the housing 3 When using a dosage tester wi...

Page 47: ...he mixed gas cylinder valve 7 Disconnect the adapter from the lung demand valve 4 2 2 4 Test with test case Prerequisites The rebreather is ready for the dosage test Work equipment Rebreather Test cas...

Page 48: ...e 4 3 Preparing the CO2 absorber 4 3 1 Removing the CO2 absorber 1 Remove the protective cover on the carrying side of the device by unhooking the side flaps 2 Loosen the tension strap fastening on th...

Page 49: ...num bag is damaged 6 Insert disposable cartridge 7 Firmly close the CO2 absorber with cover and close the bayonet lock by turning it 4 3 3 Filling the CO2 absorber with loose soda lime The rebreather...

Page 50: ...f into the bottom third of the soda lime container so that wall contact between the sealing cuff and the housing is ensured 6 Continue filling up to the filling mark while compacting the soda lime 7 C...

Page 51: ...ve pressure 1 Slowly open the cylinder valve 2 Close mouthpiece valve 3 Turn the relief valve counterclockwise up to the stop opened position 4 Check bypass valve for function press until both breathi...

Page 52: ...lease fasteners of the rebreather into the fasteners of the carrying system The rebreather should sit tight in front of the chest If necessary adjust the belt length on the rebreather accordingly 4 Se...

Page 53: ...he rebreather the dive must be stopped immediately NOTICE Coupling of the mixed gas coupling under water should be avoided Fill breathing bag Press the bypass valve Set response pressure for automatic...

Page 54: ...he CO2 absorber and turn the CO2 absorber slightly so that the connections on the breathing bags are easier to release c Remove breathing bag 2 To do this press the 3 green buttons one after the other...

Page 55: ...ber 2 Turn bayonet lock and remove cover by pulling up 3 Pour out soda lime or remove disposable cartridge Pay attention to the rubber cuff when pouring loose soda lime 4 Dispose of soda lime or dispo...

Page 56: ...ntion to breathing bag cuffs and all rubber parts X X Pressure reducer Replace sealing ring of high pressure connector X2 2 By Dr ger or trained personnel Replace O rings and control valves on the bre...

Page 57: ...the cartridge lid and cuff separately from the other parts 2 Rinse thoroughly under running water 3 All parts should be thoroughly drained then dried or disinfected if necessary 8 3 Assemblies 8 3 1 H...

Page 58: ...hing circuit with oxygen or mixed gas For this purpose the lung demand valve is connected to the inhalation bag of the breathing circuit via a plug in connector The connection of the breathing bag is...

Page 59: ...ing that is self closing on both sides It is attached to the lower left side of the housing protrudes slightly out of the housing and is therefore easy to detect with your hands even when the rebreath...

Page 60: ...the housing there are connecting pieces on both sides which connect the breathing bags with the breathing hoses and secure them in the housing The connectors each have a plug in connector with push bu...

Page 61: ...lug in connectors with red buttons the inhalation bag has green buttons According to the installation sequence the breathing bags are identified by 2 numbers Exhalation bag 1 inhalation bag 2 The inst...

Page 62: ...on side and on the exhalation side When assembling only the orientation of the valve mouthpiece has to be observed there is a mark on the mouthpiece indicating the gas flow direction The breathing hos...

Page 63: ...idelines for storage maintenance and cleaning of rubber products e g ISO 2230 10 Disposal 11 Technical data 11 1 Rebreather This product must not be disposed of as household waste This is indicated by...

Page 64: ...of the mixed gas cylinder Circuit Closed Gas type Pure oxygen according to EN 12021 Gas supply Via lung demand valve Dive time Depending on oxygen consumption Oxygen cylinder 1 5 L T 80220 Steel 200 b...

Page 65: ...der 2 L T 16991 Composite Non magnetic version based on STANAG 2897 class A 200 bar G 3 4 135 mm Approx 3 kg empty black T V Mixed gas cylinder 4 L T 16992 Composite Non magnetic version based on STAN...

Page 66: ...66 Instructions for use LAR 8000 This page has been left blank intentionally...

Page 67: ...Instructions for use LAR 8000 67 This page has been left blank intentionally...

Page 68: ...Manufacturer Dr ger Safety AG Co KGaA Revalstra e 1 D 23560 L beck Germany 49 451 8 82 0 9300157 2214 290 me Dr ger Safety AG Co KGaA Edition 2 2022 01 Edition 1 2019 09 Subject to alterations www dr...