6
General data
1. GENERAL
DATA
REMARKS
MOUVEX truck screw-type compressors MUST be installed in
systems designed by qualified personnel. The installation MUST
be in compliance with local standards, national regulations and
rules of safety.
This manual is designed to permit installation and commis-
sioning of MOUVEX truck screw-type compressors and MUST
accompany the compressor. Maintenance of MOUVEX
screw-type compressors must ONLY be carried out by qua-
lified technicians. This maintenance must meet local and
national standards as well as all safety regulations.
Read this manual, including all instructions and warnings,
in full BEFORE any use of MOUVEX compressors. Do not
remove the warning and use label stickers that are found
on the compressors.
1.1 Safety informations
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the product, or in the manual,
look for one of the following signal words and be alert to the
potential for personal injury, death or major property damage.
Warns of hazards that WILL cause serious personal injury, death
or major property damage.
Warns of hazards that CAN cause personal injury or property damage.
Warns of hazards that CAN cause personal injury or property
damage.
NOTICE
Indicates special instructions which are very important and
must be followed.
1.2 Safety check list
1.
Before operating the compressor, ensure the vessel to which
the compressor is connected is certified to withstand the pres-
sure and/or vacuum produced.
2.
Verify adequately sized relief valves have been fitted to protect
the vessel. Do not use solvents or inflammable products for
cleaning the pipelines and the accessories.
3.
Gas/air mixtures which are potentially volatile/explosive must
not be introduced or allowed to be introduced into the compressor.
4.
All pressure vessel and piping connected to the compressor must
be isolated and in a safe operating condition.
5.
Operators should wear ear protection when operating truck
mounted compressors.
6.
There are components within the compressor of sufficient weight
to cause injury if mishandled. Use proper lifting devices as
necessary.
7.
Where necessary, this equipment should be grounded to
control static electricity.
8.
The temperature of the air leaving the compressor is elevated
above ambient due to air compression. Check that the eleva-
ted temperatures do not adversely affect the product and any
material used in design of the system. Attach clearly marked
warning signs to warn of potentially hot surfaces on the com-
pressor, piping and accessories which will burn if touched.
9.
Mounting of the compressor must be correctly engineered
and the compressor must be properly secured. Refer to the
chapter
5. INSTALLATION OF THE COMPRESSOR UNIT
.
NOTICE
MOUVEX COMPRESSORS ARE NOT DESIGNED FOR HANDLING
LIQUID, POWDER OR CONDENSATE. TO DO SO WILL VOID
THE WARRANTY.
CAUTION
WARNING
DANGER