RELIEF VALVE ADJUSTMENT
This page contains the steps to making an adjustment to the relief valve.
A. Tools Required
1. 1-1/8” open end wrench
2. Ratchet with screwdriver attachment
3. 0-3000 PSI glycerin filled pressure gauge
B. Before Making Adjustments
1. MAKE SURE the unit is on flat, stable ground and apply the parking brake and chock the wheels.
2. MAKE SURE the area around the unit is clear of all unnecessary people before you operate the controls.
3. Connect an approved pressure gauge to the unit’s hydraulic circuit where it will read the relief pressure.
4. Make sure the hydraulic oil tank is full.
5. Start the unit.
6. Activate and hold the hydraulic function that activates the hydraulic relief circuit to heat the oil.
Units with Shur-Lock systems must use the tailgate lock function.
Rear loaders must use the ejector retract function.
7. Every two minutes, cycle the ejector cylinder function to mix the hot oil.
8. Continue steps 6 and 7 until the oil temperature thermometer on the oil tank reads a minimum 140° to a maximum
160°.
9. Adjust the relief pressure.
Loosen the main relief valve jam nut using the 1-1/8” open end wrench.
Rotate and hold tailgate lower switch (on outside control box).
Read the pressure gauge, it should be 2300 +/- 100 PSI.
Turn the adjusting screw OUT (counterclockwise) to decrease the pressure or turn the screw IN (clockwise) to
increase the pressure.
Tighten the jam nut when the pressure is 2300 +/- 100 PSI.
Figure 28. Pressure Relief Valve
Adjustment Location
Summary of Contents for HEIL LIBERTY TP1L-SM-0520
Page 6: ...NOTES Issued May 2020 Copyright 2020 Heil Environmental Printed in the U S A ...
Page 48: ...42 NOTES Issued May 2020 Lift Arm Copyright 2020 Heil Environmental Printed in the U S A ...
Page 110: ...104 NOTES Issued May 2020 Schematics Copyright 2020 Heil Environmental Printed in the U S A ...
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ...2 15 2018 Rev A2 ...
Page 116: ...REV ...
Page 117: ...REV ...
Page 124: ......
Page 132: ...126 NOTES Issued May 2020 Schematics Copyright 2020 Heil Environmental Printed in the U S A ...