Issued May 2020
Lift Arm
Copyright 2020, Heil Environmental
Printed in the U.S.A.
Lift Arm
56
LIFT CONTROL VALVE PRESSURE ADJUSTMENTS (CONTINUED)
B. Checking and Making Adjustments
1. Connect a 0-5000 psi pressure gauge to the gauge port on the inlet of the valve. See the image below.
Figure 21. Inlet Section Pressure Gauge Port
Figure 22. Seven Python Valve Pressure Settings
LIFT CONTROL VALVE RELIEF PRESSURE SETTINGS (PSI)
LIFT MAIN
RELIEF
LIFT UP
(RAISE) / DOWN
(LOWER)
GRABBER
OPEN / CLOSE
LIFT IN (RETRACT) /
OUT (EXTEND)
2300
2500 / 1250
1250 / 1250
2500 / 1250
Summary of Contents for HEIL LIBERTY TP1L-SM-0520
Page 6: ...NOTES Issued May 2020 Copyright 2020 Heil Environmental Printed in the U S A ...
Page 48: ...42 NOTES Issued May 2020 Lift Arm Copyright 2020 Heil Environmental Printed in the U S A ...
Page 110: ...104 NOTES Issued May 2020 Schematics Copyright 2020 Heil Environmental Printed in the U S A ...
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ...2 15 2018 Rev A2 ...
Page 116: ...REV ...
Page 117: ...REV ...
Page 124: ......
Page 132: ...126 NOTES Issued May 2020 Schematics Copyright 2020 Heil Environmental Printed in the U S A ...