The following norms are applicable based on the
used coating material:
EN 12215:2010 "Coating plants - Spray booths
for application of organic liquid coating mate-
rials - Safety requirements”.
Non-inflammable coating materials:
EN 50348:2010 "Stationary electrostatic
application equipment for non-ignitable liquid
coating materials - Safety requirements."
The control system is only intended for industrial
use.
Set up the control system only outside the explo-
sive area.
The control system actuates electrical, electro-
pneumatic and pneumatic components.
Dual piston pump with installed explosion pro-
tected asynchronous motor
Explosion-protected pressure sensor and max-
imum pressure governor
Downstream pneumatic paint pressure regu-
lator
Note technical data of the interfaces
The control system is an incomplete machine. The
control system is designed for installing in a
mechanical system.
The control system must be combined with addi-
tional signals from safety-related parts of the con-
trol systems, to correspond to European, interna-
tional and country-specific specifications on
machine safety and explosion protection.
The control system consists of a main cabinet and
can be extended by a maximum of three extension
cabinets. An additional pump can be operated for
each extension cabinet.
Only use the control system within the approved
Mount the control system on the wall or on a base
using the provided holes in the control system
Wrong use
Improper use of the control system can entail risk
of death. Adhere to the following conditions:
Do not attempt to make conversions or changes
on your own.
Do not use the control system in explosive
areas.
Do not set up control system under lines car-
rying material.
Do not exceed the maximum hose lengths and
Do not place any objects near the control
system. This is valid for electrostatically charge-
able objects.
2.3
Safety devices
The operator must implement the following safety
devices:
Emergency Stop design (Performance Level d
with category 3 according to EN ISO 13849-1)
Fire safety with extinguisher device and fire
detection system
Fire protection valve for interrupting air supply
system in the event of a fire
Mechanical ventilation (according to EN 12215
and country-specific operating specifications)
2.4
Safety signs
Danger due to electrical voltage is present in the
control system housing.
The following signs are placed on the product.
Do not remove signs from the product.
Replace illegible characters.
Safety signs
Meaning
Risk of death due to electrical
voltage exists despite switched
off main switch.
Safety sign on the front side
Fig. 3: Danger due to electrical voltage
1 Feed X01
Safety
05/2017
EcoPUC MC - MCU00003EN