Switching off extension cabinet
Fig. 20: Extension cabinet controls
2. Press
[Off]
(1) on extension cabinet.
ð
The control system is switched off.
If multiple extension cabinets are
present, switch on as described in
step 1.
Fig. 21: Switching off control voltage
3. Turn main switch (1) to the left.
ð
Control voltage is switched off.
7.4
Operating modes
The following operating modes are available:
Manual
External
UDP interface
Control panel
Fig. 22: Active mode
The active operating mode (1) is displayed in the
header row.
“Manual” operating mode
The “Manual” operating mode is preset.
Process functions are controlled manually on the
visualizer.
Start and stop the pump.
Switch between the Stand-by mode and Pro-
duction mode of the pump.
Select interval mode (only possible in Stand-by
mode).
Enable filter maintenance
Enable “External” operating mode.
“External” operating mode
Process functions are controlled though an
external control (UDP interface or control panel.
Start and stop the pump.
Switch between the Stand-by mode and Pro-
duction mode of the pump.
Select interval mode (only possible in Stand-by
mode).
Enable filter maintenance
Enable "Manual” operating mode.
Switching on “External” operating mode
1. Tap
symbol in the header row.
ð
A window is opened.
Fig. 23: Switching “External” operating mode on
and off
2. Tap the desired external control in the Drop-
down list (1).
Digital IOs = Control panel
UDP = UDP interface
3. Tap button (2).
ð
Configuration is confirmed.
4. Tap button (3).
ð
The “External” operating mode is switched
on. The button has a green border.
Operation
05/2017
EcoPUC MC - MCU00003EN
20/68