9.2
Defects table
Visualizer of typical spray pattern problems
Spray pattern
Fault identification
Spray jet is distorted.
Spray jet distinctly smaller than original (about
25%).
Spray jet is uneven.
Fault description
Cause
Remedy
No material
Feed line pinched or
broken.
Check the line.
Needle does not open.
Check Control air.
Material escapes with
the needle closed.
Needle does not close
correctly.
Check control air venting.
Check operation of needle. Replace
needle, if defective, together with
the seal retainer screw
Needle spring and
plunger spring are worn
out.
Replace needle spring and plunger
spring
Seal retainer screw, seal
washer or needle is worn
out.
Replace seal retainer screw, seal
washer and needle
Material escapes at the
needle seal.
Needle seal is worn out.
Replace needle seal
Needle gland is loose.
Tighten needle gland sensitively.
Air escapes at the end
cap.
Piston sleeve is worn out.
Replace piston sleeve
Faults
02/2020
EcoGun AA AUTO - MSG00008EN