851-702 Rev. A
9
Dorner Mfg. Corp.
3200 Series iDrive Belt Conveyors
Installation
Wiring
The 3200 series iDrive is available in 3 models:
• Cover Mounted Controls with 115 volt Power Supply
• Cover Mounted Controls with Customer Provided Power
Supply
• Customer Wired with Flying Leads
Cover Mounted Controls with 115 volt
Power Supply
1. No wiring is required. Attach quick disconnect end of
power supply to power jack
.
Figure 19
Figure 19
2. See “Change Acceleration / Deceleration Settings” on
page 11 for changing factory control settings.
Cover Mounted Controls with Customer
Provided Power Supply
1. Locate the male disconnect plug provided.
2. Wire and solder DC power to the two terminals of the
provided DC power plug. Wire +VDC to the short lug
and -VDC to the long lug
20, item 2)
.
Figure 20
Figure 20
3. Required power is 36VDC, 4 amps minimum.
4. See “Change Acceleration / Deceleration Settings” on
page 11 for changing factory control settings.
A
WARNING
Exposed moving parts can cause severe
injury. LOCK OUT POWER before removing
guards or performing maintenance.
A
WARNING
Exposed moving parts can cause severe
injury. LOCK OUT POWER before removing
guards or performing maintenance.
1
A
WARNING
Exposed moving parts can cause severe
injury. LOCK OUT POWER before removing
guards or performing maintenance.
2
1