Appendix A
Parameter and value
range, factory setting
=
bold
.
Parameter description
1
0 - 4
0
Installation type
0
• Pull arm with track, wall
mounting on swing (hinge)
side
• Pull arm and CPD lever with
track, wall mounting on swing
(hinge) side .
1
• Standard push arm,
wall mounting on approach
(non-hinge) side.
2
• Push arm with track, wall
mounting on approach
(non-hinge) side.
• Application specific
3
• Overhead concealed (OHC), right
hand (v2.1)
4
• OHC, left hand (v2.1)
2
ED50
-3 to 50
0
Reveal depth
0
Reveal is set in increments of
10 mm (3/8"), "3" = 30 mm (1
1/8").
• ED50 OHC overhead arm is
"on center" with door..
0; factory setting.
Parameter and value
range, factory setting
=
bold
.
Parameter description
3
Tb
ED50
7 to 15
10
Door width
10
Door width is set in increments of
100 mm (4"), "10" = 1000 mm (39.4").
• ED50: [700- 1219 mm] 28" - 48"
4
0 to 4
0
Door type
0
Single door
1
Double door
• Overlapping door (with astragal)
• Active door operator.
2
Double door
• Overlapping door (with astragal)
• Passive door operator.
3
Double door
• Edgeless door (no astragal)
• Active door operator.
4
Double door
• Edgeless door (no astragal)
• Passive door operator.
Appendix A - Parameters
A1.1 Configuration Parameters - Detail