29.5 ED50 OHC firmware; viewing and changing parameters
TIPS AND RECOMMENDATIONS
• Parameters descriptions incorporate
firmware versions v1.7 through v2.1.
• Version numbers are noted next to each
applicable parameter description.
29.5.1 Firmware version
Step 1
Press and hold right button greater
than 3 s to enter program mode.
Step 2
Press up or down button to scroll through
parameters until desired parameter is
displayed.
Step 3
Press right button to display current
parameter value.
Step 4
Press right button again to enable
editing of value, display will start
flashing.
Step 4
Press up or down button to select
desired parameter value.
Step 5
Press right button to save selected
value. Display stops flashing.
Step 6
Press left button to return to selected
parameter.
Step 7
Press up or down button to scroll
through parameters until next desired
parameter is displayed.
Step 8
Press left button for a minimum of 3 s
to exit program mode.
Fig. 29.5.1 dormakaba handheld
29.5.3 Configuration parameters
Configuration parameters are set during initial startup.
• Refer to Para. 29.6 for configuration parameter detail.
29.5.4 Driving parameters
Driving parameters can be set once first commissioning
has been completed.
• Reference Appendix B, Parameters for details on
each driving parameter.
29.5.5 Changing parameter values.
1. Set program switch in CLOSE position
(or no program switch).
Fig. 29.5.3 4 button keypad,
2 digit display
1
4 button keypad
2
2 digit display
> 3s Reset
< 3s Quit
> 3s
PRG
< 3s
LEARN
Fact-Setup
> 3s
> 8s
1
2
29.5.2 Firmware version and updates.
• Operator firmware version is displayed during initial
commissioning. Reference Para.
• dormakaba handheld can be used to check operator
firmware version and to perform firmware updates.
Reference Appendix C, dormakaba handheld, or
dormakaba handheld manual.
1
Program switch,
3 position
Fig. 29.5.2 Program switch
1
2. Use 4 button keypad as outlined in Steps 1 through 8
to view or change parameter values.