Chapter 34
34.1 Install fixed stop, outswing doors
Fig. 34.1.1 Fixed stop assembly DC4643-01_
1
Fixed stop
2
1/4-20 x 1 1/4"
FHMS
3
3/4" flat washer
4
1/4-20 nut
5
Bumper
1
2
2
3
3
4
4
5
5
34.1.1 Locate and drill mounting holes in
header for fixed stop.
1. Door must be in closed position.
2. Insert bumpers into fixed stop.
Reference Fig. 34.1.2 through Fig. 34.1.8.
3. With bumpers facing door, place fixed
stop against door, mark hole locations.
CAUTION
Insure fixed stop is square with
header!
4. Locate and drill two 9/32" mounting
holes; reference Fig. 34.1.2.
CAUTION
Clean any metal shavings from
header. Do not let metal shavings
fall into the door area.
39.1.2 Install fixed stop assembly in
header.
TIPS AND RECOMMENDATIONS
DK4646: kit part number for
entire fixed stop assembly,
including backing plate
1. Align backing plate mounting holes with
holes drilled in step 4.
2. Install fixed stop assembly in header,
with fixed stop bumpers facing door.
34 Install fixed stop, outswing doors
Fig. 34.1.3 Fixed stop header mounting
location, operator on RH side
4”
1”
2”
1.5”
3/4”
2 x Ø 9/32”
Fig. 34.1.2 Backing plate, fixed stop DC4644
1
Fixed stop
2
1/4-20 x 1 1/4"
FHMS
3
3/4" flat washer
4
1/4-20 nut
5
Bumpers
6
Backing plate
7
LH jamb
8
Door top rail
1
6
2,3,4
8
5
2
1
7
8
Fig. 34.1.4 Fixed stop bumpers
TIPS AND RECOMMENDATIONS
Install on outswing door if Fixed
Stop in Para. 17.7 is not installed.