51
ED100LE
02-2021
DL4616-001
dormakaba ED100LE operator – Fine cover
Installation Instructions
Chapter 18
Fig. 18.3.6 Pull arm screw kit HK2719-020
1
10-24 x 1 1/2" pan
head Philips
slotted barrel nut
DF2718-01Z
2
10-24 x 1 1/4" flat
head Philips screw
DF2717-01Z
Fig. 18.3.4 Drive arm with CPD lever installed at 15 degree angle
5
5
Fig. 18.3.5 Mounting holes for track
5
Track mounting
holes
18.3.3 Install drive arm with axle extension.
1. Install the drive arm with axle extension
(Fig. 18.3.2) onto the 8816 pinion at a
minimum angle of 15 degrees.
2. Thread M8 x 40 mm SHCS (for 20 mm
axle extension) into 8816 pinion and
tighten SHCS.
NOTICE
M8 SHCS tightening torque.
Use torque wrench (25 ft-lbs) to
tighten SHCS to 17 ft-lb [23 Nm].
18.3.4 Drill holes in door for track
fasteners.
NOTICE
Pull arm installation template.
Reference Chapter 16 for
installation template.
1. Use pull arm template to locate two
track mounting holes on door.
2. Drill two holes in door for track
mounting.
• Reference Fig. 18.3.6 for pull arm screw
kit.
NOTICE
Check hole locations for level.
Check mounting hole locations for
level prior to drilling holes.
1
2