16
79/RT/E7900/770/E-760/660 Series
PK3678_T 04-18
FDU
Program the lock using the FDU and the E-760/770/790
communication cable (see Reference Manual). If this is not a
new installation but a replacement of a single lock or a group
of locks in a property already equipped with the Kaba lock-
ing system, transfer the security information from a neigh-
bouring lock to the new lock by using the Reset Addresses
function (see Reference Manual resetting lock addresses).
ATLAS
Program the lock using the M-Unit (Maintenance Unit). Re-
fer to ATLAS User Guide.
In the case of a replacement lock resetting the addresses
will ensure that all past lost and stolen keycards remain can-
celled in the new lock and will set the addresses for the Sec-
tion, Floor, Group, Zone and Area sub-master level so that
staff keycards in use at the property will have the same pat-
tern of access to the door as before. This step makes the
lock replacement transparent so that the new lock accepts
and rejects the same keycards as the old lock.
Multihousing
Program the lock using the M-unit or EAMU FDU. Refer to
RezShield User Guide or FDU user Guide.
Aurora
Program the lock using the M-unit (Maintenance Unit) or
with command cards and Aurora software using the Aurora
software guide.
Enterprise
Program the lock using the PC M-unit (Maintenance Unit)
or with command cards and Enterprise software using the
Enterprise software guide.
5 Programming (E-760/770/79/E7900 Series)
For RT lock series, please refer to system 6000 manual.
For E7900 series, please refer to command card kit and/or software user guide