If the lock will not respond to any keycard (including the
Emergency keycard), there are four options that should be
attempted to open the door. In order, they are:
1. Verify the batteries, and replace them if they are providing
less than 4 Volts total. Use the Emergency keycard.
2. Use the electronic override feature (requires FDU and
communication cable or ATLAS M-Unit and IPM).
3. Use mechanical key override if locking system has one (see
section 9, step 8).
4. Contact Technical Support for instructions on using the
drill point.
Electronic Override Using the FDU:
If the reader fails, the E-760/770/790 lock can be opened
using the FDU (Front Desk Unit). The lock must have been
initialized by a valid FDU from the hotel where it is installed
(i.e. with the correct internal and external hotel codes), be-
fore the electronic override can be used.
Electronic Override Using ATLAS:
Refer to ATLAS User Guide.
There are two possible security levels:
Low security: IF an FDU with a software version lower than
V2.01 overrides the lock, the lock audit records only the date
and time.
High security: IF an FDU with version V2.01 or higher soft-
ware overrides the lock, the lock audit records the FDU num-
ber, the Authorization keycard number, the date and the
time.
Hardware Required
Front Desk Unit (FDU), FDU to lock communication cable
Front Desk Unit (FDU) and
Lock communication cable
Minimum Authorization Keycard Required:
Programming Authorization (PA)
Steps to activate the E-760/770/790 electronic override:
1. Insert the communication cable into the lock. Wait 2 sec-
onds then connect the cable to the serial port of the FDU.
2. Press any key to activate the FDU, then swipe a PA or
higher keycard through the FDU. If the green LED on the
lock flashes once disconnect the cable from the Serial
Port, wait 2 seconds and reconnect the cable.
Main Menu:
1 = Keycard
2 = Reset
?
3. Enter 8 to select the Programming Menu, then press <
>.
Program
1 = A lock
2 = Another FDU
?
4. Wait 2 seconds. Enter 1 to select the Lock option, and
press < >.
Enter Function
1 = Program Addresses
2 = Reset Addresses
?
5. Enter 7 to select the Override option, then press < >.
Ready to perform an electri-
cal override.
Strike a key,
or C to quit.
6. Wait 2 seconds, then press any key on the FDU to activate
the electronic override. The green LED on the lock should
light. The following message should appear on the FDU
screen immediately or within 2 seconds.
Trying to establish commu-
nication
Communication Successful
Press any key to continue.
7. Open the door. You have only 4 seconds after this message
appears to open the door.
8. Remove the communication cable from the lock.
CAUTION
WARNING
IMPORTANT
Some messages on the screen may differ depending on the
FDU version, but the menu choices are the same.
6 Operating the Electronic Override (for E-760/
770/790 Series)
For RT lock series, please refer to system 6000 manual.