2. Settings

3. Function test

The control unit is preset, i.e. If you require another

setting, you will have to implement this either with the

aid of the buttons of the 7-segment display on the

control unit (see adjustment instructions),

or via the PDA.

All connected sensors must be checked in every

program switch position.
The

must be set according to the respective

installation instructions/documentation texts.

The safety beams are automatically tested before

each closing cycle. If the test fails (the door does not

close) the system must be checked by a service

engineer.
The passage between the sliding leaves is monitored

by safety beams . If a person or an object enters the

passage or detection range of the safety beams, a

closing cycle is reversed to an opening cycle and the

door remains open until the monitored area is free and

the hold-open time has expired.

Interrupt one safety beam after the other during the

closing cycle.

The respective LED on the control unit goes out

and the door reverses.

Interrupt the safety beams for several seconds while

the door is open.

The door should remain open for as long as the

safety beams are interrupted.
Once the safety beams are uninterrupted,

the door should close on expiry of the preset

hold-open time.

Activation sensors are mostly radar sensors

responding to movements. The system is activated by

approaching people or objects.

Basic requirements:
The external activation sensor is connected and the 

program switch is set to AUTOMATIC or

PARTIAL OPEN position.
Function:

If a person or an object a ects the range of the sensor,

the door opens, and then closes on expiry of the hold-

open time.

Please note:

3.1 Safety beams (Optional-not required)
Automatic safety beam self-check

(internal test via control unit)

Manual safety beam check…
During closing cycle:

While the door is open:

3.2 External activation sensor

Function test.

sensors

·

·

·

3.3 Internal activation sensor
Function test.

Basic requirements:

Function:

3.4 Night-/ Bank Function
Function test.

Basic requirements:

Function:

3.5 Breakout Switch

Basic requirements:

Function:

3.6 Locking device

3.7 Monitoring of closing and opening force
Obstruction during closing cycle:

If the door leaves run up against an obstruction during

the closing cycle, the closing cycle is reversed into an

opening cycle. The door opens to its full width. The

door then closes at low (creep) speed until the hold 

open time expires. This sequence is repeated until

the obstruction is removed.
Obstruction during opening cycle:

Function test.

The internal

must be connected and

the program switch must be set to AUTOMATIC,

EXIT ONLY or PARTIAL OPEN position.

If a person or an object a ects the detection range of

the sensor, the door opens, and then closes on expiry

of the hold-open time.

The Night-/ Bank contact is connected and the

program switch is set to

CL

O

SE

.

Activate the system with the

.

The door is unlocked and opens.
Once the user has passed the door or on expiry

of a

d hold-open time, the door closes and

locks in the closed position.

The program switch must be set to AUTOMATIC,

PARTIAL OPEN, EXIT ONLY,

CL

O

SE

(not locked) or

PERMANENT OPEN.

Breakout any panel.

The door leaves stop immediately
The door can be moved manually.

The door is in close position, it is locked, when the

program switch is set to OFF, AUTOMATIC or

EXIT ONLY.

If the door leaves open against an obstruction, the

door stops, then performs a further opening attempt at

low (creep) speed. If the obstruction is still present, the

door stops again. After a total of six opening attempts

the door closes. Once the obstruction is removed, the

next opening cycle is performed at low (creep) speed.

Then the door resumes operation at the preset speed.

activation sensor

Night-/ Bank contact

·
·

·
·

ESA II Controller

and Wiring Manual

DORMA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

          4 

DORMA AUTOMATICS, Inc.   

 

924 Sherwood Drive 

 

 

Toll-Free: 877-367-6211   

        DL2842-010

 

 

 

 

 

Lake Bluff, IL  60044 

 

 

Fax: 877-423-7999 

 

 

   rev. A

 

 

 

 

 

E-mail: [email protected] 

 

 

  Subject to change without notice

Summary of Contents for ESA II

Page 1: ...Manual DORMA ESA II CONTROLLER AND WIRING MANUAL DORMA AUTOMATICS Inc 924 Sherwood Drive Toll Free 877 367 6211 DL2842 010 Lake Bluff IL 60044 Fax 877 423 7999 rev A E mail automatics dorma usa com Subject to change without notice ...

Page 2: ...reakout cutoff switch Without breakout cutoff switch Program switch Motion detector presence sensor BEA Motion detector presence sensor profusion Bircher Reglomat Panic closing function Electric lock Airlock Contents 1 2 3 4 4 5 5 6 6 7 7 8 9 10 12 13 14 14 15 15 16 16 17 17 18 19 20 21 22 23 29 Page ESA II Controller and Wiring Manual DORMA 1 DORMA AUTOMATICS Inc 924 Sherwood Drive Toll Free 877 ...

Page 3: ...SING Acceleration OPENING Acceleration CLOSING OPENING Force limitation CLOSING Power supply data Fuse Power supply for external accessories Power consumption max max 30 in s 12 in s 4 in s 4 in s 9 9 9 180 s 60 s 10 s open 12 inch 12 inch 9 9 70 lb 70 lb min 4 4 1 1 1 1 1 1 5 s 1 5 s 0 s 10 0 0 1 1 11 lb 11 lb in s in s in s in s inch inch inch 120 V 10 50 60 Hz 27 V DC 2 A 6 6 A not exchangeable...

Page 4: ...t The door opens at low creep speed to determine the opening width The opening parameters are now stored and an 8 flashes twice on the 7 segment display The learning cycle is now complete The 7 segment display indicates a dot The door closes at normal speed Test of opening cycle Set program switch to AUTOMATIC and push the SERVICE SELECT button The door performs an opening cycle and is closed afte...

Page 5: ...est sensors 3 3 Internal activation sensor Function test Basic requirements Function 3 4 Night Bank Function Function test Basic requirements Function 3 5 Breakout Switch Basic requirements Function 3 6 Locking device 3 7 Monitoring of closing and opening force Obstruction during closing cycle If the door leaves run up against an obstruction during the closing cycle the closing cycle is reversed i...

Page 6: ...sing edges with the DCW address 48 IN 1 and IN 2 See connection diagram of function module Presence sensors monitor the side lite safety area For example the opening cycle towards the wall for systems without safety screens Securing the main closing edge IN3 See connection diagram of function module 4 2 Setting the Panic Closing Function IN 4 see wiring diagrams of function module The Panic Closin...

Page 7: ...SE position Airlock function 4 5 Door status contact 2 OUT 2 Disabling of airlock if required 4 6 Panic Closing Function IN 4 Door status contact 1 OUT 1 4 7 Bell contact OUT 4 Wear parts We recommend to conclude a maintenance contract with DORMA Cleaning Door 2 is disabled during the opening cycle of door 1 internal and external are deactivated The locking function is disabled as soon as the door...

Page 8: ... below is CLOSE and or Radar 2 inputs the door will open After opening signals received from the Presence input or the Safety Beams will cause the door to remain open open again when the door is closes After all the sensors have cleared the hold open delay is initiated and when it expires the door will close Continuous Open Operation The door opens to the full opening width and remains in this pos...

Page 9: ... door reaches the desired partial opening width set the program switch to PARTIAL OPEN and the main switch to close The door stops The control unit stores the desired position The door performs a closing cycle The program switch is set to AUTOMATIC PARTIAL OPEN or EXIT ONLY After a power failure the control unit performs a self check of approx 5 sec for safety reasons The door then closes at low c...

Page 10: ...short the input If the fault is cured by this check supply voltage 27 V of the basic module and the sensors If it is okay check and replace sensors if required Replace or trim screw 7 Troubleshooting The 27 V power supply for radar motion detectors the locking device etc is short circuit proof In the event of a short circuit both control LED lights of the safety beams go out and the 7 segment disp...

Page 11: ...cription and terminal connections ESA II Controller and Wiring Manual DORMA 10 DORMA AUTOMATICS Inc 924 Sherwood Drive Toll Free 877 367 6211 DL2842 010 Lake Bluff IL 60044 Fax 877 423 7999 rev A E mail automatics dorma usa com Subject to change without notice ...

Page 12: ...urce 1 5A Power supply GND EMERGENCY OFF Inhibit GND Power supply Battery Battery Interconnection LON Adapter Service interface to PDA External activation Internal activation Presence 2 Presence 1 Service Power supply Battery Motor 27 V DC 27 V DC 27 V DC 27 V DC 27 V DC 27 V DC DCW Interface 27 V DC Signal A Signal B Incremental encoder 27 V DC 27 V DC 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 2...

Page 13: ...Panic closing function Door status contact 1 DOOR OPEN Door status contact 2 DOOR CLOSED Door status contact 3 OPERATIONAL FAULT Door status contact 4 Bell contact Disable airlock Entrance disables the door Panic closing function Door status contact 5 Door closed Door status contact 6 Disable airlock exit Door status contact 7 Airlock impulse exit Door status contact 8 Bell contact 1 2 ON 1 2 ON 1...

Page 14: ... p t u o l a t i g i D h c t i w s P I D Motor e l u d o m n o i t c u F e t i h w H W n w o r b N B n e e r g N G w o l l e y E Y y e r g Y G k n i p K P e u l b U B d e r D R k c a l b K B t e l o i v T V k n i p y e r g K P Y G 1 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 1 2 3 4 5 6 7 8 9 10 11 12 13 A S E ...

Page 15: ...H BK YE RD Power supply 120 V AC 60 Hz 35 V DC Wiring diagram of the motor control system and power supply Control system ESA II basic module _ _ Wiring diagram Night Bank open Control system NIGHT BANK contact Description and terminal connections 7 8 GND ESA II Controller and Wiring Manual DORMA 14 DORMA AUTOMATICS Inc 924 Sherwood Drive Toll Free 877 367 6211 DL2842 010 Lake Bluff IL 60044 Fax 8...

Page 16: ... optional Wiring diagram without breakout cutoff switch 32 33 Control system Description and terminal connections Bipart dual magnets shown single magnet for single slide Magnetic switch Control system ESA II basic module _ _ Control system ESA II basic module _ _ ESA II Controller and Wiring Manual DORMA 15 DORMA AUTOMATICS Inc 924 Sherwood Drive Toll Free 877 367 6211 DL2842 010 Lake Bluff IL 60...

Page 17: ...NT OPEN 1 2 3 4 5 6 Description and terminal connections GND Control system ESA II basic module BN WH 27 V DC GND Battery Attach ONLY for the functional test and immediately before the commissioning Disconnect the battery before servicing the ESA II Battery Fuse 10A Control system ESA II basic module Wiring diagram of the battery optional Control system Battery Description and terminal connections...

Page 18: ... 21 Inside LE2 NPN 22 27v 23 Inside LE2 GND 24 Ground 25 27v 26 Outside LE1 NPN 27 27v 28 Outside LE1 GND 29 Ground 30 31 32 33 34 Wiring diagram motion detector presence sensor BEA and Bircher Reglomat Control system ESA II basic module Wizard Outside 24v 24v Common No Common Safety Wizard Inside 24v 24v Common No Common Safety Red Black White Green Brown Blue Red Black White Green Brown Blue Bir...

Page 19: ...5 Radar Outside 16 Ground 17 27v 18 Radar Inside 19 Ground 20 27v 21 Inside LE2 NPN 22 27v 23 Inside LE2 GND 24 Ground 25 27v 26 Outside LE1 NPN 27 27v 28 Outside LE1 GND 29 Ground 30 31 32 33 34 Wiring diagram motion detector presence sensor BEA Control system ESA II basic module Optional 24v 24v Common No Nc BEA MICRO CELL ONE Red Black White Green Brown Wizard Outside 24v 24v Common No Common S...

Page 20: ...ress 49 or Adress 48 Does not meet BHMA ANSI 156 10 This function overrides all safety devices Door will close if switch is activated IN IN GND 27 V DC Control system Panic closing OFF ON Wiring diagram panic closing function Panic switch Function setting via PDA ESA II Function module _ _ ESA II Controller and Wiring Manual DORMA 19 DORMA AUTOMATICS Inc 924 Sherwood Drive Toll Free 877 367 6211 D...

Page 21: ...m Lock Description and terminal connections H W GR N B Wiring diagram for electric lock Feedback signal contact N B H W Control system ESA II basic module _ _ ESA II Controller and Wiring Manual DORMA 20 DORMA AUTOMATICS Inc 924 Sherwood Drive Toll Free 877 367 6211 DL2842 010 Lake Bluff IL 60044 Fax 877 423 7999 rev A E mail automatics dorma usa com Subject to change without notice ...

Page 22: ...OUT 1 NO C NC Digital input Digital output 21 20 16 14 13 12 19 18 17 15 IN IN 4 Lock disabled own door is blocked out Lock disabled other door is blocked out Wiring diagram for airlock GN YE WH BN WH GN YE BN No setting at the PDA required Door A ESA II function module _ _ Door B ESA II function module _ _ ESA II Controller and Wiring Manual DORMA 21 DORMA AUTOMATICS Inc 924 Sherwood Drive Toll F...

Page 23: ...or increasing the parameter or value indicated DOWN push button for decreasing the parameter or value indicated SEL Push button for MENU control SERV Push button for performing the functions of the service push button SELECT Service ESA II Controller and Wiring Manual DORMA 22 DORMA AUTOMATICS Inc 924 Sherwood Drive Toll Free 877 367 6211 DL2842 010 Lake Bluff IL 60044 Fax 877 423 7999 rev A E mai...

Page 24: ...ld open time Hold open time Side lite function Opening speed Closing speed Display codes 0 F 0 1 0 1 0 3 0 3 0 9 F 0 9 F 0 1 0 d 0 4 Operation mode Menu level Parameter SELECT automatically after 20 sec SELECT SELECT Modifying the parameters of the system using the push buttons and select At t the following sequense must be observed when setting the parameters 1 check and switch if necessary 2 che...

Page 25: ... 5 sec 2 5 sec 5 sec 8 sec 10 sec 15 sec 20 sec 25 sec 30 sec Adjustment via PDA 30 sec Side lite function Stop Closing cycle The hold open time adjusted via the PDA is also indicated on the 7 segment display of the control unit As the display of the control unit follows a certain pattern see above it always indicates the next value below For example Adjustment of PDA 14 sec display of control uni...

Page 26: ...ameter error Motor fault Battery test error Force test Overcurrent at motor DCW Query of error messages Only the current error can be acknowledged The errors must be corrected before resetting Up to 10 errors can be stored regardless of type Additional error displays appear in the PDA ESA II Controller and Wiring Manual DORMA 25 DORMA AUTOMATICS Inc 924 Sherwood Drive Toll Free 877 367 6211 DL2842...

Page 27: ...MERGENCY OPEN mode wait until force test in open position porduces OK Overcurrent at motor longer than 30 sec Turn program switch to CLOSE Change direction of motor rotation During commissioning door panels open During the cycle press Turn p A D P e h t y b d e d r o c e r e b y l n o n a c s r o r r e e s e h T s e d o c y a l p s i d f o g n i n a e M 3 2 6 1 5 1 k c o L 2 2 h c t i w s m a r g ...

Page 28: ...unit LED status indicator Start push button Infrared device Connecting port for PDA RJ45 LED SUB D ESA II Controller and Wiring Manual DORMA 27 DORMA AUTOMATICS Inc 924 Sherwood Drive Toll Free 877 367 6211 DL2842 010 Lake Bluff IL 60044 Fax 877 423 7999 rev A E mail automatics dorma usa com Subject to change without notice ...

Page 29: ...rvice key Software upload from PDA to service key See ESA ASP data base recording The service key must contain the latest software version Take the sliding door out of operation set Program switch to CLOSE or use the EMERGENCY OFF push buttonif necessary Press and hold the start push button for three seconds The LED status indicator on the service key s orange while it performs the update It s red...