Terminal 21 to 23 and terminal 26 to 28 must have a N.C. circuit.
ESA II Controller
and Wiring Manual
DORMA
17
DORMA AUTOMATICS, Inc.
924 Sherwood Drive
Toll-Free: 877-367-6211
DL2842-010
Lake Bluff, IL 60044
Fax: 877-423-7999
rev. A
E-mail: [email protected]
Subject to change without notice
1
2
3
4
5
6
7
8
9
10
11
12
13
14 - 27v +
15 - Radar Outside
16 - Ground
17 - 27v +
18 - Radar Inside
19 - Ground
20 - 27v +
21 - Inside LE2 (NPN)
22 - 27v +
23 - Inside LE2 (GND)
24 - Ground
25 - 27v +
26 - Outside LE1 (NPN)
27 - 27v +
28 - Outside LE1 (GND)
29 - Ground
30
31
32
33
34
Wiring diagram motion detector / presence sensor (BEA) and (Bircher Reglomat)
Control system ESA - II basic module
Wizard
Outside
(24v +)
(24v -)
(Common)
(No)
(Common)
(Safety)
Wizard
Inside
(24v +)
(24v -)
(Common)
(No)
(Common)
(Safety)
Red
Black
White
Green
Brown
Blue
Red
Black
White
Green
Brown
Blue
Bircher Reglomat
Profusion - Outside
(24v +)
(24v -)
(Common)
(No)
(Common)
(Safety)
Bircher Reglomat
Profusion - Inside
(24v +)
(24v -)
(Common)
(No)
(Common)
(Safety)
Brown
White
Gray
Yellow
Red
Pink
Brown
White
Gray
Yellow
Red
Pink