Technical Data
·
= yes
·
·
·
·
setting range
Function programs
Close
AUTOMATIC
PERMANENT OPENING
PARTIAL OPENING
EXIT
Parameter
Opening speed
Closing speed (up to 190 lb)
Creep speed OPENING
OPEN braking deceleration OPEN
Brake ramp CLOSE
Brake ramp reversing
Hold open time
Delayed opening
Partial Opening
Force limitation
Creep speed CLOSING
Brake ramp
Hold open time NIGHT/BANK
NIGHT/BANK
Creep speed distance OPENING
Creep speed distance CLOSING
Acceleration OPENING
Acceleration CLOSING
OPENING
Force limitation CLOSING
Power supply data
Fuse
Power supply for external accessories
Power consumption: max.
max.
30 in./s
12 in./s
4 in./s
4 in./s
9
9
9
180 s
60 s
10 s
open
12 inch
12 inch
9
9
70 lb
70 lb
min.
4
4
1
1
1
1
1
1.5
s
1.5
s
0 s
10
0
0
1
1
11 lb
11 lb
in./s
in./s
in./s
in./s
inch
inch
inch
120 V +/- 10%
50/60 Hz
27 V DC / 2 A
6.6 A not exchangeable
250 W
ESA II Controller
and Wiring Manual
DORMA
2
DORMA AUTOMATICS, Inc.
924 Sherwood Drive
Toll-Free: 877-367-6211
DL2842-010
Lake Bluff, IL 60044
Fax: 877-423-7999
rev. A
E-mail: [email protected]
Subject to change without notice