![Dorma ES 410 Mounting Instruction And Operation Manual Download Page 6](http://html1.mh-extra.com/html/dorma/es-410/es-410_mounting-instruction-and-operation-manual_2522651006.webp)
W
N
0
5
8
0
2
2
4
5
5
3
2
1
1
/1
1
DORMA
Montageanleitung
Mounting instruction
ES 410 / 420
0
6
Safety during mounting
·
The working area has to be secured against unauthorised
access from other people. Falling items or tools might
cause injuries.
·
The
ES 410 / 420
has to be secured against water and
other liquids.
·
In any case, the way of mounting and the mounting
equipment, like for example screws and wall plugs,
have to be adequate with regard to the structural
conditions (steel structure, wood, concrete etc.).
·
The mounting of the
ES 410 / 420
described herein is
only an example. Structural or local conditions,
available tools or other conditions might suggest a
different approach.
·
Following the successful installation of the system, the
settings and the proper function of the
ES 410 / 420
and the safety equipment have to be
checked.
·
Only specially qualified staff may open the power
supply housing.
·
Disconnect the
ES 410 / 420
from power supply (de-
energise the system) before removing the cover of the
power supply housing. Remove mains plug or switch off
fuse (with permanent power supply).
·
Always pull at the plug and never at the cable when
unplugging the power supply.
Safety during commissioning
·
The protective earth conductor has to be connected.
·
The safety sensors are to be connected (see
commissioning instructions).
·
The operator and the active panels are properly linked.
·
The end stops are adjusted so that the sliding panels
meet the end stops when the system is adjusted to its
maximum opening width
·
Furthermore the sealing profiles of the active panels
and the passive panels must not collide while the door
is closed
·
Separately supplied components such as the program
switch, the EMERGENCY OFF pushbutton and
activators (radar motion detectors, NIGHT-/BANK key
switches) have to be mounted and connected.
·
Ensure that the door leaves run smoothly
·
The rechargeable battery pack has been installed
(optional).
Inspection and system approval
Before the first commissioning and depending on
requirements, however, at least once a year,
the
ES 410 / 420
has to be inspected by a properly
qualified technician and serviced if required.
A person trained by DORMA has to perform the inspection
and approve the system with the aid of the inspection
book.
The respective results have to be documented in
accordance with DIN 18650-2 and the facility operator
has to keep these documents for at least one year.
We would recommend taking out a maintenance
agreement with DORMA.
Briefing
Following the adjustment, commissioning and functional
testing of the door system, the operating instructions have
to be handed over to the facility operator and a briefing
has to be made.
Behaviour of door system during varying weather
conditions
The safety sensors (infrared light curtains) are designed to
safeguard the passage area. When it comes to adjusting
the sensitivity of the sensors, the protection of people
always has top priority. From time to time, changing
climatic conditions (such as rain or snow), flying leaves or
direct sunlight (reflected by certain floor finishes) may
accidentally trigger the sensors. As soon as the light
curtains have been triggered, the door may remain open
for up to one minute – as required by a certain standard.
This is only a standard procedure with the only purpose to
protect the users of the door system.
Maintenance
The system has to be de-energised (disconnected from
power supply) before performing any kind of maintenance
work.
Remove the power plug or switch off the fuse (with
permanent power supply).
Care
Set program switch to OFF or PERMANENT OPEN mode
in order to avoid an undesired movement of the door while
cleaning the system.
You may clean the complete door system (aluminium,
glass, cover) with a damp cloth and a standard
commercial cleaning agent
You should not use scouring agents for cleaning purposes
as they might damage the surface finish.
Use a dry cloth to clean the light barriers. Clean the floor
guides
Ensure that no water or other liquids drop on or into the
ES 410 / 420
.
Never stick metal objects into the openings of the
ES 410 / 420
otherwise you might sustain an electric
shock.
Wear parts
The following wear parts have to be inspected at regular
intervals during the maintenance of the door system and
must be replaced as required in order to ensure the proper
functioning of the door system:
• The operator
• The pulleys of the carrier heads
• The end stops
• The equipotential bondings
• The pulley
• The toothed belt
Only use original spare parts.
6