9150-065-M-5-18
2
5
ON
ON
REVERSE
SENSITIVITY
REVERSE
LOOP
EXIT
LOOP
FULL OPEN
DOORKING
4602-010
SW1
SW3
SW2
OPEN
TIMER
NC
NO
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
10
1
ON
2
3
4
1
ON
2
3
4
CLOSE Edge/Beam Reverse:
Obstructed reversing edge or photo beam will reverse the gate to the open position
during the closing-direction only.
•
After the gate reverses to the open position, the close-timer
will time out and close the gate (if it is turned on).
•
If a second sequential obstruction is encountered prior to the
gate reaching the close limit, the gate will
reverse to full open
position
and enter a soft shutdown condition (See page 34).
OPEN Edge/Beam Reverse:
Obstructed reversing edge or photo beam will reverse the gate to the close position
during the opening-direction only.
•
After the gate reverses to the close position, any
opening input will cycle the gate again.
Note: If the gate is opening by a time clock and a edge/beam
gets obstructed, the gate will return to the closed position
and another input (automatic exit loop, reverse loop, remote
etc.) is needed to cycle the gate open again.
UL 325 Terminal and LEDs
Connect
ONLY MONITORED
Devices
UL 325 DIP-Switches
115 VAC Convenience
Outlets
1 - OPEN Beam STOP (Switch 1)
2 - Ground (Common)
3 - CLOSE Beam REVERSE (Switch 2)
4 - Ground (Common)
5 - 24 VAC 250 mA Max (don’t exceed this)
6 - Ground (Common)
7 - OPEN Edge/Beam REVERSE (Switch 3)
8 - Ground (Common)
9 - CLOSE Edge/Beam REVERSE (Switch 4)
10 - Ground (Common)
1 - OPEN Beam
2 - CLOSE Beam
3 - OPEN Edge
4 - CLOSE Edge
SECTION 4 - ENTRAPMENT AND SAFETY PROTECTION
4.1 UL 325 Terminal Description
Closed Gate
Wall / Fence
Open Beam
Open Beam
Wall / Fence
Filler Post if necessary
Closed Gate
Wall / Fence
Close Beam
Closed Gate
Wall / Fence
CLOSE Beam Reverse:
Obstructed closing-direction
photo beam will reverse the gate to the open position and
reset the close-timer
during the closing-direction only.
Gate will close when timer times out.
Closed Gate
Ground (Common):
Common terminal for all MONITORED entrapment protection device inputs.
1
3
7
9
OPEN Beam Stop:
Obstructed opening-direction photo
beam will stop the gate
during the opening-direction only.
Gate will resume the open cycle when the obstructed photo
beam has been cleared.
Open Edge
Open Edge
Close Edge
Entrapment Area
Entrapment Area
Entrapment Area
Entrapment Area
WA
RNING
MOV
ING GA
TE CA
N CA
US
E
Op
era
te g
ate
on
ly w
hen
ga
te a
rea
is in
sig
ht
and
fre
e o
f p
eop
le a
nd o
bstr
uc
tion
s.
Do
no
t all
ow
ch
ildr
en t
o p
lay
in g
ate
are
a
or o
pe
rate
ga
te.
Do
no
t sta
nd i
n g
ate
pa
th o
r wa
lk t
hro
ugh
path
w
hile
ga
te is
m
ovin
g.
Rea
d o
wn
er’s
m
anu
al a
nd s
afe
ty in
stru
ctio
ns.
SER
IO
US IN
JU
RY
OR
DEAT
H
CLA
SS
CER
TIF
IED
TO
CAN
/CS
A
C22
.2
NO
. 2
47
CO
NFO
RM
S T
O
AN
SI/U
L-3
25
VEH
ICU
LA
R GA
TE O
PE
RA
TO
R
HP
533
82
MO
DE
L
SER
IAL
VO
LTS
PH
AS
E
AM
PS
60 H
z
MA
X G
ATE
LO
AD
Doo
rKin
g, In
c., In
gle
wo
od,
CA
ON
ON
RE
VE
RSE
SE
NSITIV
ITY
RE
VE
RSE
LO
OP
EX
IT
LO
OP
KEY
SWI
TC
H
DOORKI
NG
460
2-0
10
SW
1
SW2
OP
EN
TIM
ER
NC
1
2
3
4
5
NO
UL 325 LEDs:
LED ON:
Connected device has been activated.
LED remains off during normal operation.
LED Flashing:
Connected device is in fault.
Wiring to device is bad.
2, 4, 6, 8 & 10
Close Beam
DIP-switches
MUST
be turned
ON
for
each device wired to
terminal.
Monitored Device Note:
Only 1 monitored Device can be
connected to each input. An
OPTIONAL
Expansion Board
(sold separately) will allow connection for additional devices.
UL 325 Terminal #5 Note:
Exceeding 250 mA of power from this terminal
may cause the circuit board transformer to
overheat, causing intermittent problems.
External Entrapment Protection Devices:
In addition to the inherent reversing sensor system, this operator has a UL 325 terminal for the connection of
photo sensors
-Type B1 and/or
reversing edges
-Type B2 entrapment protection required by UL 325 standards.
Entrapment Protection must be provided for the gate system
where the risk of entrapment or obstruction exists. The operator will not run without one or more monitored type B1 or B2 entrapment
protection devices.
Install these devices where the risk of entrapment or a safety hazard exists, examples of which are shown below and the
next 2 pages. Specific installations will vary.
Summary of Contents for 9150-080
Page 50: ...9150 065 M 5 18 46...