6.3 Manual Gate Operation

Fail-Safe

 Manual Release System (Factory Installed)

This operator is equipped with one of two types of manual release systems, 

“Fail-Safe”

 (required by many city codes) or 

“Fail-Secure”

 that will allow the gate to be pushed open in the event of a power outage or equipment failure.  

This manual release system is the most reliable and safest method for placing the gate operator in manual 
operation.

 It is the preferred method of emergency gate operation under worse case conditions by many Fire Chiefs 

and Building Inspectors and is 

typically used in Class I and Class II applications.

 This system is accessible from 

either side of the gate and requires 

NO

 keys, cranks or other tools to manually operate the gate. This prevents any 

delays for emergency vehicle access in the event of a power outage. The operator “Fails” (Loss of AC power) in a 
“Safe” (Manually operable) condition.

Solenoid lock does 

NOT

 secure the clutch plate 

during an 

AC power failure

 or 

turning AC power off

.

 Gate can be 

immediately manually operated during these conditions.

Solenoid lock 

WILL

 retract and secure the clutch plate during 

normal operation 

ONLY

 if operator senses an 

UNAUTHORIZED

 

manual open attempt. Gate will 

NOT

 be allowed to move.

Caution: NEVER attempt to manually push open any gate with an operator attached to it until you 

have VERIFIED that power to the operator has been SHUT-OFF!

Solenoid Lock 

Clutch Plate 

SW 2, switch 4 
must be 

OFF

ON 

12

 3
 

4

5
6 7 8 

SW 2 

Note: DoorKing operators have a built-in alarm reset push button mounted on the operator above the power ON-OFF 
toggle switch. Activating this button will return the gate operator to normal operation, but will not cycle the gate 
operator. A remote alarm/reset station (P/N 1404-080) can be mounted external of the gate operator provided that it 
is installed in the line-of-sight of the gate and gate operator.

The operator is in a hard shutdown condition when the audio alarm is sounding OR “chirping” every 5 seconds.

Once the gate has been reset, an open or close command is needed to start the gate operator. Most activating 
commands will cause the gate operator to cycle to the open position. This includes activation of a key switch or 
open command and activation of an automatic exit loop. Activation of a close command will run the gate to the 
closed position.

  Before resetting a hard shutdown, determine why the shutdown occurred. Inspect the gate for any 

  obstructions along its path that could have activated the inherent entrapment sensing system. Inspect 
  the gate and gate hardware.

The gate operator 

WILL NOT

 lose its open and close positions after resetting a hard shutdown.

Resetting a Hard Shutdown

The audio alarm will sound for five minutes, or until the operator’s reset button is pushed. After (5) five minutes the 
alarm will “chirp every 5 sec.” and the hard shutdown condition will remain in affect until the reset button is pushed.

Summary of Contents for 9150-080

Page 1: ...N G GATE CAN CAUSE Op erate ga te on ly wh en ga te area is in sig ht an d fre e of pe op le an d ob str uc tio ns Do no t all ow ch ild ren to pla y in ga te area or op erate ga te Do no t sta nd in...

Page 2: ...ition Normal Setting Gate fully closes Gate stops short 1 from full close position Used for a reversing edge device Gate stops short 2 from full close position Used for a reversing edge device Gate st...

Page 3: ...hen gate is open auto close timer SW 1 switch 2 is turned ON input will re set and hold timer When gate is open auto close timer SW 1 switch 2 is turned OFF input will prevent gate from closing When g...

Page 4: ...1 Minimum 10 5 Use this manual for the Model 9150 operator with circuit board 4602 010 Rev AA or higher ONLY Chain Height Idler wheels in top position Concrete Pad Concrete Pad Operator Specification...

Page 5: ...Switch 6 2 Shutdown Conditions 6 3 Manual Gate Operation 33 34 35 35 36 SECTION 8 OWNER OF GATE OPERATOR 43 8 1 Alarm Sounding and Gate WILL NOT Operate 8 2 Manual Gate Operation 8 3 Gate Operators Mo...

Page 6: ...age and page 26 A gap measured in the horizontal plane parallel to the roadway between a fixed stationary object nearest the roadway such as a gate support post and the gate frame when the gate is in...

Page 7: ...an is required to perform their intended function Physical Stops Permanently mounted and easily visible from either side of the gate Warning Signs Non Contact Sensors Photo Sensors 1 2 Minimizes the p...

Page 8: ...reduce reversing sensitivity to compensate for a damaged gate For gate operators utilizing Type D protection 1 The gate operator controls must be placed so that the user has full view of the gate area...

Page 9: ...s are installed a minimum distance of 6 feet away from the gate and gate operator or in such a way that a person cannot touch the gate or gate operator while using the device If access control devices...

Page 10: ...lar gate operator or system intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public in whic...

Page 11: ...or vehicular traffic flow at entrances or exits to areas such as parking garages lots or toll areas VEHICULAR HORIZONTAL SLIDE GATE OPERATOR OR SYSTEM A vehicular gate operator or system that controls...

Page 12: ...ps Gate End Retainer Helps stabilize the end of the gate in the open or closed position Recommended for all slide gate applications Endless Idler Assembly with Protective Cover Helps to minimize a pin...

Page 13: ...path while gate is moving Read owner s manual and safety instructions SERIOUS INJURY OR DEATH CLASS CERTIFIED TO CAN CSA C22 2 NO 247 CONFORMS TO ANSI UL 325 VEHICULAR GATE OPERATOR HP 53382 MODEL SER...

Page 14: ...l stop for the gate Both are shown only one type is needed Base Plate Stop Bracket Chain Setup Chain Setup The Model 9150 operator is designed to be installed in the front rear center or ceiling mount...

Page 15: ...oorKing Rear Position with Concrete Pad Hides the chain from outside the property looking in Chain setup is the same as above Rear Position with Post Mount Hides the chain from outside the property lo...

Page 16: ...operty looking in Optional chain tray kit can be used and is recommended for gates over 20 ft supports the chain s weight and helps prevent chain stretching See page 17 for more information Note Chain...

Page 17: ...r and Communication wires Loop Lead In Wires Low Voltage wire insulation AC Input Power High Voltage wire insulation AC Input Power High Voltage wire insulation 3 4 Inch Conduit Recommended The condui...

Page 18: ...Weld the posts to the base plate and mount assembly into concrete BEFORE attaching the operator Conduit runs up through 6 x 6 steel posts Note Operator must be mounted 1 min away from gate Low Volt H...

Page 19: ...t Lines up with Idler Wheels Correct Chain Bracket Height Correct Chain Bracket Height Chain brackets positioned too low NO NO NO NO Chain Idler Wheels 1 minimum from operator housing to gate YES YES...

Page 20: ...wheel wear and chain stretching Lower chain MUST align with upper chain Upper and lower chain MUST be the same height as they are on the operator idler wheels NO NO NO Gate Rail Gate Rail Chain Bracke...

Page 21: ...e chain DoorKing offers a chain tray kit in sections to fit any length gate DoorKing P N 2601 270 10 Ft section Chain Tray Supporting Bracket Facing down Chain Tray Supporting Bracket Facing up Weep H...

Page 22: ...er than the maximum distance shown it is recommended that a service feeder be installed When large gauge wire is used a separate junction box must be installed for the operator connection The wire tab...

Page 23: ...th local codes Be sure to color code all wiring It is recommended that a surge suppressor be installed on the high voltage power lines to help protect the operator and circuit board from surges and po...

Page 24: ...ng bar on the N O or N C pins respectively SW 1 switches 4 and 5 must be set to control relay See next page for descriptions 1 23 Auto Close Timer Dual Channel Loop Detector Single Channel Loop Detect...

Page 25: ...g on a green light when the gate is full open If a magnetic lock is used with the gate operator these switches must be set for magnetic lock operation which limits the relay to activate only when the...

Page 26: ...entry If switch 2 is turned OFF Reverse the closing gate that gets activated by a tailgating vehicle will reverse back to the open position possibly allowing the tailgating vehicle unauthorized entry...

Page 27: ...powered up the first open command will automatically run Multiple gate cycles that will locate and remember the gate s open and close positions These positions are determined by the physical stops tha...

Page 28: ...tment Test the operator reversing sensitivity Press the Key Switch button to cycle the gate While gate is cycling slowly rotate reverse sensor clockwise until the gate reverses direction Rotate revers...

Page 29: ...ntrapment protection device inputs 1 3 7 9 OPEN Beam Stop Obstructed opening direction photo beam will stop the gate during the opening direction only Gate will resume the open cycle when the obstruct...

Page 30: ...added above the 27 5 height 5 or Less 5 or Less DIP switches 1 2 and 3 ON 1 ON 2 3 4 UL 325 Terminal Connect ONLY MONITORED Devices 1 OPEN Beam 2 CLOSE Beam 3 OPEN Edge 4 CLOSE Edge Only 1 monitored...

Page 31: ...0 mA Max Don t exceed this 6 Ground Common 7 OPEN Edge Beam REVERSE Switch 3 8 Ground Common 9 CLOSE Edge Beam REVERSE Switch 4 10 Ground Common Normally Closed Normally Closed Normally Closed Close E...

Page 32: ...exiting vehicles without having to use a transmitter or keypad The exit loop can be placed a minimum of 4 feet away from the reverse loop or far enough away from the gate so the gate has started or c...

Page 33: ...opened or in the closing cycle When gate is open auto close timer SW 1 switch 2 is turned ON input will re set and hold timer When gate is open auto close timer SW 1 switch 2 is turned OFF input will...

Page 34: ...ens 14 feet Relay N O 2 Full Open 5 Opens gate 14 feet 250 mA max 3 Wire Radio Receiver ON 1 2 3 4 5 6 7 8 SW 2 SW 2 switch 3 must be OFF Relay Com 24 Volt Com 24 Volt 250 mA max 4 Wire Receiver 5 Ter...

Page 35: ...This system can keep track of gate operator cycle count shorted inputs loop detector problems any forced entry attempts if the gate has struck anything during the open or close cycle power interrupti...

Page 36: ...or Connect 4 to 10 fully opens gates Open Beam Note If Open beam is required for entrapment protection 1 and 2 UL 325 terminals MUST be wired in parallel between primary and secondary operators SW 2 s...

Page 37: ...a rigid object or stop or reverse when an object activates the non contact sensors After adjusting the force or the limit of travel retest the gate operator Failure to adjust and retest the gate opera...

Page 38: ...gate will reverse and run back to the closed position The time clock input is still present but the gate will not re open Example 2 If the gate is closing and an entrapment protection device is activa...

Page 39: ...that power to the operator has been SHUT OFF Solenoid Lock Clutch Plate SW 2 switch 4 must be OFF ON 1 2 3 4 5 6 7 8 SW 2 Note DoorKing operators have a built in alarm reset push button mounted on th...

Page 40: ...s truc tion s Do not allow child ren to play in gate area or ope rate gate Do not stan d in gate path or walk thro ugh path whil e gate is mov ing Rea d own er s man ual and safe ty inst ruct ions SE...

Page 41: ...hen an obstruction is encountered Check for alignment tightness and wear Check vehicular exit and reverse loops for proper operation Check manual release for proper operation See page 44 Pulleys Check...

Page 42: ...used with this gate operator Others will cause a malfunction 6 Check the high voltage supply A voltage drop on the supply line usually caused by using too small supply voltage wires will cause the ope...

Page 43: ...m excess wires can diminish magnetic field Check that the magnetic pickup transistors on control board are within 1 8 inch of the clear plastic protective cover above the black plastic magnetic spring...

Page 44: ...ect wire cable contains all the necessary wires to interconnect primary secondary operators Cable length 30 ft P N 2600 755 40 ft P N 2600 756 50 ft P N 2600 757 Time Clock 7 day time clock can be use...

Page 45: ...4 3 2 1 Brown White White Green Black Black White White Black White Red Yellow White Chassis Ground Board Ground Convenience Outlets Power Neutral Model 9150 1 2 HP 115 VAC Reset AC Power Alarm 115 VA...

Page 46: ...e Green Black Black White White Black White Red Yellow White Chassis Ground Board Ground Convenience Outlets Motor Resistors Power Neutral Model 9150 1 HP 115 VAC Reset AC Power Alarm 115 VAC Yellow Y...

Page 47: ...times before the gate completes the open or close cycle 2 The reversing edge contact sensor Type B2 gets activated and reverses but before the gate completes the reverse cycle the inherent entrapment...

Page 48: ...NS for more information about operating this gate operator Gate CANNOT be manually PUSHED open until FAIL SECURE Lock has been UNLOCKED WARNIN G MOV IN G GA TE CA N CA US E Ope rate gat e onl y whe n...

Page 49: ...he gate will resume opening when the beam is clear If gate does NOT respond like it should in either direction of gate travel contact a trained service technician to make adjustments or repairs Test R...

Page 50: ...9150 065 M 5 18 46...

Page 51: ...R GA TE OP ER ATO R HP 5338 2 MO DEL SER IAL VOL TS PHA SE AM PS 60 Hz MA X GAT E LOA D Doo rKin g Inc Ingl ewo od CA P o w e r S w i t c h C o v e r RESET BUTTON Note If gate operator does NOT have a...

Page 52: ...Phone 310 645 0023 Fax 310 641 1586 THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY Visit www dkslocator com to find a professional installing and servicing dea...

Reviews: