3.1 4602 Circuit Board Description and Adjustments
SECTION 3 - ADJUSTMENTS
The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is
complete.
Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then
turned back on for the new setting to take effect. Every time
the 9150 is powered up, the
First
open command will automati-
cally run “
Multiple gate cycles”
that will locate and remember the gate’s open and close positions (See page 23).
Auto-close timer (when
turned on) SW 1, switch 2.
Adjust from 1 second
(full counter clockwise) to
approximately 23 seconds
(full clockwise).
Dry relay contacts
(terminals 15-16) can be
set for Normally Open
(NO) or Normally Closed
(NC) operation by placing
the relay shorting bar on the
N.O. or N.C. pins respectively.
SW 1, switches 4 and 5 must
be set to control relay. See
next page for descriptions.
1
23
Auto-Close Timer
Dual Channel Loop Detector
Single Channel Loop Detector
Dry Relay Contact
NC
NO
Set the DIP-switches
on the circuit board
to the desired
setting. See switch
setting charts on
next 2 pages.
DIP-Switches
ON
1
2
345678
SW 2
ON
1
2
345678
SW 1
ON
1
2
345678
SW 1
LEDs
Indicates that low voltage power is applied to the circuit board.
Input LEDs
should be OFF
and will only illuminate when the input is activated.
Pulse LEDs
will blink as the operator is
running. They can be either ON or OFF when the operator is stopped.
Full Open
Adjust reversing sensitivity.
Full counter clockwise for
minimum sensitivity, full
clockwise for maximum
sensitivity. See page 24.
Min
Max
Sensitivity
Inherent Reverse Sensor
UL 325
Terminal
Pages 25-27
UL 325
DIP-Switches
Pages 25-27
Power LED
Pulse LEDs
Input LEDs
UL 325 LEDs
Magnetic
Sensors
See page 24.
ON
12
3
45
678
SW 1
Typical Settings
Exit Loop Port
Reverse Loop Port
See page 28.
See page 32.
Cycles the operator
when pressed. Gate
opens to full open
position ONLY. It will
use the Auto-Close
timer when turned ON.
Summary of Contents for 9150-080