![Door entry online K301A User Manual Download Page 5](http://html1.mh-extra.com/html/door-entry-online/k301a/k301a_user-manual_2521088005.webp)
SPECIFICATIONS
6
Operating Voltage:
12V-24V AC/DC, Auto adjusting
Operating Current:
20mA (quiescent) to 90mA@12VDC
10mA (quiescent) to 45mA@24VDC
Storage and Operation Temperature:
-20 C to +70 C
Storage and Operation Humidity:
5-95% relative humidity non-condensing
Working Environment & Ingress Protection:
All weather, IP-66
Number of Users:
Output 1 – 1,000 (User Codes) + 50 Duress Codes
Output 2 – 100 (User Codes) + 10 Duress Codes
Number of Visitor Codes:
50, programmable for one time or with time limit
Timings for Code Entry:
10 seconds waiting for next digit entry
The Timers:
1-99,999 Seconds (Over 24 Hours possible) Independent Programmable Timers for O/P 1 & 2
Egress Button:
Programmable for Instant, Delay with Warning
Momentary or Holding Contact for Exit Delay
Input Sensing Terminals:
a) Door position, b) Egress, c) O/P 1 inhibit
Output Control Terminals:
Transistor Open Collector 24VDC/100mA sink Max for the following outputs
a) Duress, b) Key Active, c) Inter-lock
Output Contact Ratings:
Output Relay 1 – N.C. & N.O. dry contacts, 5A/24VDC Max.
Output Relay 2 – N.C. & N.O. dry contacts, 1A/24VDC Max.
Tamper Switch – N.C. dry contact, 50mA/24VDC Max.
Dimensions:
125(H) X 79(W) X 46/54(D)mm
Weight:
510g net
Housing:
Die-Cast Aluminum, Powder-paint coating
Faceplate Material:
1.5mm stainless steel
Doorentryonline
Ltd