Door entry online K301A User Manual Download Page 13

14

5) To program a new Master Code to replace the old one. See “

Record A Master Code

 

stated at 

“Location 01” for the details.

NOTE:

The keypad will set itself to normal operation mode 1 minute after power-up if the Egress Button is 

not pressed and the DAP code is not keyed in. To set keypad back to power-up mode, repeat 

procedures 1-4.

SYSTEM REFRESHING WITH “REFRESHING CODE” --- 9 9 9 9                        

       

The keypad can be refreshed by cleaning all the programmed old data and set it back to default 

values except the

 Master Code

.

      
                       

     

REFRESHING CODE                          VALIDATION

   

NOTE:

a) 
b) 
c)

 

Make sure that system refreshing is really required before entering the refreshing code.
Refreshing takes few minutes. The status LED (amber) keeps flashing during refreshing.
The keypad is back to its default value after refreshing. Re-program of the desired values are 

necessary.

DIRECT ACCESS TO PROGRAMMING MODE WITH “DAP” CODE -- 2 8 2 8             

               

In case the Master Code is forgotten, apply the following procedures precisely to set keypad 
into programming mode with DAP code:

1) 

2) 

 

3) 

4) 

Switch OFF all the power for 1 minute to ensure that the keypad is fully discharged.

Switch ON power again. The keypad is in Power-up Mode for 1 minute. The buzzer gives 

continuous beeps and the Status LED is flashing. This is the only time frame to accept the DAP 

code.

Press the Egress Button (the button connecting accross EG IN, (Terminal 9) and (-)GND, 

(Terminal 15) once to enable the keypad for accepting DAP code. The power-up beep stops after 

the Egress Button is pressed.

Key in the DAP code                    and validate it with             (or             ). The Status LED is 
ON and the keypad is in programming mode like using Master Code. It is ready to accept new 
programming data as long as you like until exit programming mode.

.

.

PRESS ONCE

EGRESS BUTTON                      DAP CODE                        VALIDATION

Doorentryonline 

Ltd

Summary of Contents for K301A

Page 1: ...VANDAL RESISTANT BACK LIT WEATHERPROOF ACCESS CONTROL KEYPAD K301A User Manual MK II FOR ELECTRIC LOCK INTER LOCK AND SECURITY SYSTEM INSTALLATIONS D o o r e n t r y o n l i n e L t d...

Page 2: ...e User Codes For Output 1 2 Examples Programming And Operation Visitor Codes For Output 1 Only Duress Codes For Outputs 1 2 Operation And Function of The Duress Code Output Modes Timing for Output 1 a...

Page 3: ...Modes Close The Programming Mode Programming General Users Programming Summary Chart Application Examples Stand alone Door Lock Inter Lock System Using Two Keypads 38 38 39 40 41 42 43 42 43 D o o r...

Page 4: ...optional controllers reader keypads for system expansion Loaded with the K301A MK II operation software Built in with all the logics for stand alone split decoded and multi station operations Controls...

Page 5: ...try The Timers 1 99 999 Seconds Over 24 Hours possible Independent Programmable Timers for O P 1 2 Egress Button Programmable for Instant Delay with Warning Momentary or Holding Contact for Exit Delay...

Page 6: ...system for testing In previous experience most of the damages caused in the installation are accidental touching of the components on circuit board with the wires carrying power Please be patient to s...

Page 7: ...and N O output for Fail secure locking device The relay is programmable for Start Stop toggle mode or Momentary timing mode See programming Location 51 for the details 6 7 8 OUTPUT 2 Output Relay 2 1...

Page 8: ...terminal 2 13 DOOR SENS N C Door Position Sensing Input Normally Close A Normally Closed N C sensing point referring to ground with the help of a normally closed magnetic contact monitors the open or...

Page 9: ...nnection with the partner keypad s O P 1 Inhibit point in an Inter lock system to prevent both doors can be opened at the same time An Inter lock System An inter lock system is a two door system that...

Page 10: ...ash in 1 Second Interval 8 System Refreshing 9 Code Already Stored in System Fast Flashes for 2 5 Minutes 1 Long Beep Continuous 3 Fast Beeps 5 secs Continuous 1 Beep 5 secs 11 Real time clock stopped...

Page 11: ...ep indication Example User 13579 24680 1234 3456 Output 1 Output 1 Output 1 Output 1 004 003 002 001 10 10 10 10 Tracy 5678 Output 2 001 20 Bill Tom May John Name Location User ID Code Remark 1 2 3 4...

Page 12: ...ming mode with 2 beeps d DO NOT turn off power while the keypad is in programming mode Otherwise it may cause error to the data in memory PROGRAMMING OPERATION POWER UP THE KEYPAD The keypad gives pow...

Page 13: ...desired values are necessary DIRECT ACCESS TO PROGRAMMING MODE WITH DAP CODE 2 8 2 8 In case the Master Code is forgotten apply the following procedures precisely to set keypad into programming mode w...

Page 14: ...er Program Required 9 4 Operation Modes Code 0 Keypad Mode 6 0 Personal Safety Lock out Code 1 10 False Code Lock out 60 Sec 7 0 User Code Entry Mode Code 2 Manual Entry Mode 7 1 7 2 O P Operation Ann...

Page 15: ...ration 2 1 3 Press key once Two beeps confirms the entry Example Set a Master Code 2 2 3 3 01 SUPER USER CODE Location 02 The Super User Code has TWO functions It is prepared to operate the three outp...

Page 16: ...Toggle NOTE 3 Pause The Scheduled Daily Inhibition for Output 1 Temporarily Disable The Inhibition The scheduled inhibition can be programmed and applied to Output 1 with daily start and stop times It...

Page 17: ...k control is inhibited all the User Codes for it become invalid and those people holding the User Code are refused This function Starts Stops in toggle with the following code entry Door Lock Operatio...

Page 18: ...d User ID Delete a user code by keying in its ID 0999 Group Clearing Clear all the User Codes of the selected User Group Location Clearing takes few seconds to a minute 3 USER ID The IDs of The User C...

Page 19: ...eration mode a Key in the User Code 2 4 6 8 b Confirm it with the key Output 1 activates 2 Example 2 User Code for Output 2 i Programming a The User Code is programmed for Output 2 b Record a User Cod...

Page 20: ...Two beep confirms a valid entry and the User Code in that User ID is cleared 4 Example 4 Clear The Whole Group of Users Whole group of users can be cleared with the following command a b c a The User...

Page 21: ...or Code can be set with the valid time limit of 1 Hour to 99 Hours with a two digit number of 01 to 99 The visitor code is cleared when the time limit reaches 4 8 DIGITS 40 01 50 00 or 01 99 VISITOR C...

Page 22: ...ee hours a b c d e a Visitor Code Programming b The Visitor ID c Valid for 3 Hours d The Visitor Code e Example 3 Delete a Visitor Code from Vistor ID 02 in the memory a b c a Visitor Code Programming...

Page 23: ...Duress Code IDs for The Output 2 0999 Clear all the Duress Codes from the selected Location group Please see the programming example below for the details 3 THE DURESS CODES 50 and 10 Duress Codes can...

Page 24: ...User Code The Duress Code always activates the Relay Output in its group but does not de activate stop the Duress Output ONLY a normal User Code in anyone of the user groups or a Super User Code can...

Page 25: ...is entered the output Stops when an User Code is entered again Seconds Momentary Default Momentary 5 Seconds The output can be set in Momentary Mode with the time of 1 second to 99 999 seconds The out...

Page 26: ...count in 24 hour basis from the programmed current time Programming Examples a Set the current time of 10 30 AM to the keypad b Set the current time of 6 45 PM to the keypad IMPORTANT NOTE 1 The real...

Page 27: ...me inhibition starting time in Hour and Minute The allowed time figure is 00 00 23 59 The starting time is based on 24 hours daily with the first two digits for hours and the last two digits for minut...

Page 28: ...ion Examples i Set the starting and stopping time for the real time inhibition period a Set Inhibition Period from 12 30 PM today 1 30 PM same day for lunch time b Set Inhibition Period from 6 30 PM t...

Page 29: ...Selection of after 5 to 10 successive User Code trials the keypad locks during Example Release the lock up 00 Disappearance of all the above lock up securities 3 VALIDATION Press key once Two beeps co...

Page 30: ...digit length of the Master Code Manual Entry increases the level of security in code trial by the unauthorized people 3 VALIDATION Press key once Two beeps confirms the entry PACIFIER TONES ON OFF SEL...

Page 31: ...n when the output relay activates 3 VALIDATION Press key once Two beeps confirms the entry STATUS LED FLASHING ON OFF DURING STANDBY Location 73 1 LOCATION Key in Location 2 FUNCTION MODES FOR STANDBY...

Page 32: ...ithout using Code or Egress Button Warning b The door is opened with Code No Warning c The door is opened with Egress Button No Warning 3 VALIDATION Press key once Two beeps confirms the entry DOOR PR...

Page 33: ...alues WHERE AND WHY GOING OUT NEEDS ATTENTION Examples for some areas may need an Intelligent Egress Button Hospital Some of the patients are not allowed to leave the ward without doctor s permission...

Page 34: ...is usually closed and watched by guards The egress button of this keypad can be programmed to offer exit delay with warning beeps and even gives alarm output to trigger an alarm system when the door...

Page 35: ...released when the delay time reaches CONFIGURATIONS VALIDATION DELAY TIME LOCATION 1 5 0 or 1 99 90 Press the Button once No warning or alarm is given during Egress Delay Good for silent area The peop...

Page 36: ...Example 3 Set Egress Button in Momentary contact without delay This is the default setting a b c d a Egress function programming b Momentary contact without delay c Release door instantly d Entry conf...

Page 37: ...eaders keypads for multi station expansion Server Mode Server Mode sets the keypad to compatible with both the decoder for split decoded operation and the auxiliary readers keypads for multi station e...

Page 38: ...e until the end of power up delay or keyin to stop the power up delay instantly and set the keypad to normal operation 1 Set System in Programming Mode with The Factory Set Master Code 0 0 0 0 2 beeps...

Page 39: ...O P 2 01 10 DURESS CODE 4 8 Digits 41 CODE ID DURESS CODE CODE ID NIL 4 2 Duress Code for O P 2 42 NIL 5 1 O P Mode for O P 1 OUTPUT MODE TIME 0 Start Stop 1 99999 Seconds START TIME 00 00 23 59 STOP...

Page 40: ...ected location are cleared Exit Programming Code The system back to normal opration after programming Pacifier Tone ON OFF 7 1 FUNCTION MODE 0 NO Notification 2 2 Short Beeps 1 1 Second Long Beep FUNC...

Page 41: ...EMF to prevent it from damaging the keypad The 1N4004 is not required if the electric lock is AC operated To avoid Electro Static Discharge from interfering with the operation of the keypad always gro...

Page 42: ...und to achieve the inter lock logical functions Use keypad to open the door from outside Press egress button to open the door from inside Connect the door magnetic sensors on the doors to monitor thei...