![Door entry online K301A User Manual Download Page 39](http://html1.mh-extra.com/html/door-entry-online/k301a/k301a_user-manual_2521088039.webp)
40
PROGRAMMING SUMMARY CHART
LOCATION
FUNCTION
ENTRY LIMITS & CODE
OPTIONS
CODE ENTRY
FACTORY
DEFAULT
0 1
Master Code
4-8 Digits
01
MASTER CODE
#
NIL
0 2
Super User
Code
4-8 Digits
02
SUPER USER CODE
#
NIL
10
User
Codes for O/P 1
CODE 1
-
MEDIA:
2---Private User Code
5---Deletion of User Code
CODE 2
CODE 3
-
USER CODES:
4-8 Digits
-
USER ID:
000-999---Group 1(10)
001-100---Group 2(20)
10
CODE1
CODE2
CODE3
#
NIL
20
User
Codes for O/P 2
20
NIL
4 0
Visitor Codes
CODE 1
-
VISITOR ID:
01-50
CODE 2
-
VALID PERIOD:
00---One Time
01-99 Hours
CODE 3
-
VISITOR CODE:
4-8 Digits
40
NIL
4 1
Duress Code for O/P 1
CODE ID
-
O/P 1:
01-50
CODE ID
-
O/P 2:
01-10
DURESS CODE:
4-8 Digits
41
CODE ID
DURESS CODE
CODE ID
#
NIL
4 2
Duress Code for O/P 2
42
#
NIL
5 1
O/P Mode for O/P 1
OUTPUT MODE & TIME:
0--- Start / Stop
1---99999 Seconds
START TIME:
00:00-23:59
STOP TIME:
00:00-23:59
5 6
Start & Stop Times
for Inhibition
56
STOP TIME
START TIME
#
NIL
CURRENT REAL TIME:
00:00-23:59
5 5
Real-Time-Clock
55
CURRENT TIME
#
NIL
51
O/P MODE & TIME
#
5 Seconds
5 2
O/P Mode for O/P 2
52
O/P MODE & TIME
#
5 Seconds
CODE1
CODE2
CODE3
#
CODE1
CODE2
CODE3
#
DURESS CODE
6 0
Personal Safety &
Lock-Up
LOCK-UP CODE:
1---10 Trial, Lock-Up 60 Sec.
2---10 Trial, Activates Duress
5-10---5-10 Trial, Lock-Up 15
Minutes
00---No Lock-Up
60
LOCK-UP CODE
#
Code = 1,
10 Trials,
Lock-Up 60
Seconds
7 0
Code Entry Mode
ENTRY MODE:
1---Auto Mode
2---Manual Mode
70
ENTRY MODE
#
Mode =
2, Manual
Mode
Doorentryonline
Ltd