DONATI SERVICE
DONATI
TECHNICIAN
54
INSTRUCTIONS JIB CRANE SERIES GBA - GBP
MAN05MGO5
•Checkthestabilityofthearmwhenemptyandwhenfullyloaded,attheendpointsandintermediatepointsof
rotation; then checking that the arm, in any point of the rotation, keeps its position with moving
spontaneously.
• When necessary have the brake of the crane adjusted, as described in paragraph 6.4.1 “Adjustment of the
rotation brake of the crane arm”, on page 56.
•Checktheefficiencyofthefestoonedpowercable,checkthereisnopeeling,cuts,lacerationsorotherchanges
in the protection sheath.
•Checkthesealoftheprotectors,thepowercable,theirclamps(intheconnectorblock)and,ifnecessary,tighten
them correctly.
•Checktheefficiencyoftheconductorsandthegroundingconnections,carryingoutacheck,and,ifnecessary,
fixing all the grounding screws.
•Carryoutacheckofalltheweatherstripsofthecoversandthecableclamps.
•Checktherearewarningplatesandthattheyarevisible.
Quarterlycheckoftheefficiencyofthebrakeoftherotationarmofthecrane:
Quarterlycheckoftheefficiencyoftheelectricpowersupply:
• Replace the clutch plates of the brake when there is instability of the arm after
adjustingthebrake.
INCASEOFANOMALIES:
•Itisforbiddentocarryoutcorrectivemaintenanceworkonthebrakeoftherotation
armofthejibcrane.
•Anyoperation,outsidenormalmaintenance,onthebrakeoftherotationarmofthe
cranecanbedonebytheassistanceserviceofDONATISOLLEVAMENTIS.r.l.orby
staffauthorizedbythem.
•Donothesitatetoreplacetheelectricalcomponent,ifitisnolongergivingsufficient
guaranteeoffunctionalreliability
•Nevercarryoutimprovisedrepairs
•Useoriginalspareparts
For information about checks of all the structural, mechanical and electromechanical components of
tehliftingandtranslationunitsofthejibcrane,seetherelevantdocumentationincludedinthis
technical publication
•Don’thesitatetoreplacethepartand/orthecomponentinquestion,whenitnolongergives
sufficientguaranteeofsafetyand/orfunctionalreliability.
•Nevercarryoutimprovisedrepairs!
KMAN05MG05