37
16.8
Technical specifications
Max. consumption
kg/h
2.4
Power. kW
29
Motor power.
W
110 W
Adjustment type
On/Off
Electric voltage
220 V - 50 Hz
16.9
Recommended nozzle and pump pressure
The Fusion Hybrid Oil module is supplied with the burner mounted, with its corresponding nozzle
and a standard pre-adjustment. The following table specifies the nozzle and corresponding
adjustments:
MODEL
Nozzle
Burner pressure
(bar)
Air adjustment
Line adjustment
30 HFD
0.55 60° H
13.5 4 1.5
16.10
Oil supply piping diagrams
The diagrams and tables below correspond to installations without reductions and with a perfect
hydraulic seal. It is recommended to use copper pipes. A pressure drop of 0.4 bar (30 cmHg) must
not be exceeded.
Intake installation
H- Pipe
length
(m)
int 8 mm.
int 10 mm.
0.0 34 82
0.5 30 72
1.0 25 62
1.5 21 52
2.0 17 42
2.5 13 32
3.0 9 21
3.5 6 16
Charging installation
H+ Pipe
length
(m)
int 8 mm.
int 10 mm.
0.5 36 80
1.0 42 90
1.5 46 100
2.0 50 100
Intake installation
H-
Charging installation
H+
H+