Fusion Hybrid Oil
20
6
OPERATION
The
Fusion Hybrid Oil
module is an oil supporting module of the
DUAL CLIMA
heat pump. Therefore,
its operation will be fully managed by the
DUAL CLIMA
heat pump controllers connected to it, which
should be mounted on the front of the module (see
“Assembly and connection of the control panel”).
It must be ensured that parameter
P27
of the Technical menu of the
DUAL CLIMA
heat pump is at
value 3 and that parameter P26 of the Technical menu of the DUAL CLIMA heat pump is at value 0.
This ensures the correct management of the
DUAL CLIMA
heat pump with the supporting module.
6.1
Switching on the module
Selection of the module temperature setpoint.
The boiler setpoint temperature range selectable by the heating thermostat
(20)
is 60-80°C. The
Fusion Hybrid Oil module is a support module, so, in order to obtain maximum performance and
subsequent energy savings in operation, it is advisable to select a setpoint temperature of 60-70°C,
provided that the system of installed heating and the insulation conditions of the home allow it.
6.2
Operation in “auto” mode
This will be the default operating mode of the
Fusion Hybrid Oil module
(with the ACS selector (23)
and the heating selector (22) in auto position. In this mode, the operation will be managed by
the
DUAL CLIMA
heat pump, as indicated in the instruction manual of the heat pump according to
configuration
P27 = 3
. See
“Configuration of auxiliary or supporting energy sources”
.