17
BIOCLASS iC 150
The fill level detection sensor for the pellets is supplied already set by the factory, therefore there is no
need to adjust it unless it has become maladjusted during transport.
2-3 mm
Filling sensor
Fill indicator
The various automatic fuel suction system components must be connected pneumatically using a hose
with an interior diameter of 50 mm, preferably a flexible plastic hose with electrostatic charge
accumulation protection.
To ensure the system is correctly connected and sealed, the boiler includes 4 coupling flanges for fixing
the hose ends to the respective pneumatic components.
The figure below shows the connection diagram of the fuel suction system:
Bucket
A
B
Canvas
Silo
B
A
Nozzle for
construction site
A
B
Bucket
A
B
Run a pipe from the main storage silo (intake
A
) to the boiler reserve tank and connect it to the cyclonic
suction intake, (intake A) located on the rear part of the same. Run a pipe from the cyclonic air pipe
(intake
B
) to intake B of the canvas silo or working nozzle.