OPERATION
4-40
EPT019297 Issue 1 November 2016
Add a Prompted Field Element
When a label containing a prompted field element is sent to print, the operator will be prompted to
update data in the prompted field element before printing can start.
The type of data that can be entered into a prompted field element can be Time, Date or Text.
To add a prompted field element into the label design:
(1) In the
Side
menu select the
Element
tab.
(2) Select the
Add
menu.
(3) Select
Text
.
(4) Select
+Variable
at the top of the screen.
(5) Select
+Create new...
(6) Select
Prompted field.
(7) The following prompted field settings can now be defined:
(8) Select the green
Tick
icon to confirm the prompted field settings.
(9) Select the green
Tick
icon to add the prompted field element to the label design.
(10) Select the
Save
icon to save the change.
End of procedure.
Setting Name
Explanation
Name
Enter the name of the prompted field element.
Type
Select the type of pompted field:
None - The user will be prompted to enter standard text.
Clock - The user will be promtped to enter a date.
Time Conditional - The user will be prompted to enter a time.
Prompt
Enter a prompt message which will be displayed to the operator to
prompt when the label is sent to print.
Input mask
If Type is set to None, enter the number and type of characters
which the operator must input.
If Type is set to Clock or Time Conditional, enter the format the
operator must user to input the date or time.
Output format
Enter the format which the clock or time will be printed in.
Note:
This setting is only valid if Type is set to Clock or Time
Conditional.
Language
Select the clock or date language.
Note:
This setting is only valid if Type is set to Clock or Time
Conditional.
Summary of Contents for Ax Series
Page 1: ......
Page 2: ... 2 EPT019297 Issue 1 November 2016 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 5: ...EPT019297 Issue 1 November 2016 5 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 7: ...EPT019297 Issue 1 November 2016 7 ...
Page 12: ...HEALTH AND SAFETY 1 2 EPT019297 Issue 1 November 2016 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 18: ...SYSTEM DESCRIPTION 2 2 EPT019297 Issue 1 November 2016 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 36: ...INSTALLATION 3 2 EPT019297 Issue 1 November 2016 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 77: ...OPERATION EPT019297 Issue 1 November 2016 4 3 Alert ID Codes 4 66 Fault Finding 4 72 ...
Page 78: ...OPERATION 4 4 EPT019297 Issue 1 November 2016 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 148: ...MAINTENANCE 5 2 EPT019297 Issue 1 November 2016 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 167: ......