21
8.7
Checking the oil level
!
I
Always check the oil level before use. To do this, proceed as follows:
➤
Open the generator front door.
➤
Switch the generator to no function with the main switch (fig.
4
1, page 5).
➤
Disconnect the positive terminal of the supply battery.
➤
Take the dipstick (fig.
4
2, page 5) out of the filler neck (fig.
4
3, page 5).
➤
Clean the dipstick (fig.
4
2, page 5) with a cloth.
➤
Put the dipstick (fig.
4
2, page 5) back into the filler neck (fig.
4
3, page 5).
➤
Take the dipstick (fig.
4
2, page 5) out of the filler neck.
➤
Check that the oil level is between the notch (maximum filling level) and the tip of
the dipstick (fig.
4
4, page 5).
If not, top up with more oil.
➤
Put the dipstick (fig.
4
2, page 5) back into the filler neck (fig.
4
3, page 5).
➤
Check that the oil level is not above the maximum level.
➤
Connect the generator to the positive terminal of the supply battery.
➤
Switch the generator to standby with the main switch (fig.
4
1, page 5).
➤
Close the generator front door.
CAUTION!
Hot oil can cause burns.
Only check the oil level when the generator is switched off.
NOTE
The generator must be level.