EN
TEC29 EV, TEC 29 EV LPG
Troubleshooting
29
11
Troubleshooting
Fault
Cause
Remedy
The remote con-
trol does not come
on when the
on/off switch is
pressed.
Starter battery is flat.
➤
Charge the starter battery.
Power cable is disconnected or the plug
is removed.
➤
Contact an authorised workshop.
Generator earth cable is disconnected or
the fuse (if available) is blown.
The starter does
not work when the
start button is
pressed.
Starter battery is flat.
➤
Charge the starter battery.
The main switch is at “0”.
➤
Set the main switch to “I” or “1”.
Starter shaft is dirty.
➤
Clean the starter shaft.
Too much oil in the engine.
➤
Drain the oil.
Inverter is damaged.
➤
Contact an authorised workshop.
Power cable is disconnected or the plug
is removed.
Generator earth cable is disconnected or
the fuse (if available) is blown.
Starter is not receiving any power.
The starter turns
but the generator
does not start.
No petrol/LPG.
➤
Fill up with petrol/LPG.
Spark plug is not receiving any power.
➤
Check the electric connections.
Carburettor is not receiving any petrol.
➤
Clean the carburettor.
Air intake is blocked.
➤
Check the air filter (see chapter
“Servicing the air filter (fig.
7
,
page 6)” on page 27).
The ambient temperature is below 0 °C.
➤
Use pure propane gas.
Inverter is damaged.
➤
Contact an authorised workshop.
Power cable is disconnected or the plug
is removed.
TEC29EV-TEC29EVLPG--O-16s.book Seite 29 Mittwoch, 3. Mai 2017 4:45 16