4.4 UNIT READINGS MENU
Menu Heading
Selections / Adjustments Range
Default Setting
Unit Readings
DC
11.68V
0.0A
Read Only
AC INPUT
0 A
0 V
0 Hz
VAC OUT
120 V
60.0 Hz
Temperature
Batt: 20.0°C
Trans: 30.5°C
Fets: 30.6°C
SHORE POWER
UNIT READINGS
INVERTER
ON/OFF
CHARGER
ON/OFF
ENTER / SET
BACK
UNIT SETUP
REMOTE SETTINGS
®
SHORE POWER
UNIT READINGS
INVERTER
ON/OFF
CHARGER
ON/OFF
ENTER / SET
BACK
UNIT SETUP
REMOTE SETTINGS
®
DC Status
11.68 V
0.0 A
AC INPUT
0 A
0 V
0 Hz
1. DC STATUS
The first value: 11.68 V displays the voltage (VDC) from the battery bank
connected to the
Inverter/Charger
. This reading is displayed with a 0.01 VDC
resolution.
The second value: 0.0A displays the battery current (VDC) either being dis-
charged (inverting mode) or charged (charging mode) from/into the battery
bank.
A negative value, e.g. -35.0A shows that the batteries are dis-charging and
the
Inverter/Charger
is inverting.
A positive value, e.g. 40.0A shows that the batteries are charging and the
Inverter/Charger
is in charging mode.
State indicator: PT - Pass Through; PS - Powershare; CHG - Charging; INV:
Inverting
2. AC INPUT
The first value is showing the total AC Amps being used by the inverter for
charging and for powering any AC Loads. This reading is always displayed
as a positive number. If the charger is using 15A to charge the batteries
and the connected AC load is using 10A then the total AC Input value is
displayed as 25A.
The second value is showing the voltage (AC) of the connected AC Power
source (Utility or Generator). This will usually read 120V.
The third value is showing the frequency of the connected AC Power source
(Utility or Generator). This is displyed as a unit of frequency: Hertz (Hz).
3. VAC OUT
PT
OPERATION