EN
Installing and connecting the DC kit
DC-Kit PP12, DSP-T12/24
20
➤
Install the remote control.
D
7.3
Connecting air conditioning unit FJ1100, FJ1700,
FJ2200, FJ2700, FJ3200
➤
Remove the air outlet unit of the air conditioner; if necessary remove the top
cover (
FreshJet) (fig.
5
, page 6).
➤
Connect the on/off cable for the FreshJet to the connection socket on the circuit
board (fig.
6
, page 7).
I
PP12
Circuit diagram: fig.
1
, page 3
➤
Route the on/off cable from the air conditioning unit to the charging current
distributor.
➤
Connect the on/off cable to connections I4 and I2 on the charging current
distributor (fig.
4
, page 6).
➤
Connect the inverter adapter (
Inverter Adapter).
➤
Attach the air outlet unit of the air conditioner (
FreshJet) (fig.
5
, page 6).
➤
Route the connecting cable for remote control MCR9 to the inverter and connect
it (
inverter).
DSP-T12/24
Circuit diagram:
•
DC-Kit DSP-T12: fig.
2
, page 4
•
DC-Kit DSP-T24: fig.
3
, page 5
➤
Connect the adapter cable to the on/off cable.
➤
Connect the extension cable to the adapter cable.
➤
Connect the extension cable to connections I2 and I5 on the charging current
distributor (fig.
4
, page 6).
DANGER! Electric shock!
Only connect the battery once you have the completed all the installa-
tion work and you are certain it has been done properly.
NOTE
Guide the on/off cable carefully past the fan.
DC-Kit-PP12-DSP-T--IO-16s.book Seite 20 Freitag, 29. Juni 2018 7:17 19