Programmable alarm relay
The device is equipped with programmable
potential free alarm relays, which are activated
when the unit shuts down and jumps to an error
mode. The alarm relays are deactivating again
when the error has been resolved and the device is
running in normal operating mode again.
The following alarm relays are activated when the
device shuts downs:
• MT ICC 1600 SI-N: alarm relay
• MT ICC 3000 SI-N: relay 1
After the AC supply becomes available the follow-
ing relays will be activated:
• MT ICC 1600 SI-N: alarm relay
• MT ICC 3000 SI-N: relay 2
MT ICC 3000 SI-N: In case of battery operation,
relay 2 will deactivate immediately. This can be
used e.g. to signalize AC input presence on the
board control, or to switch less critical AC loads
(i.e. electric boiler, A/C) on and off that are
allowed to be supplied by the mains or alternator
only.
Both normally closed and normally open contacts
of these relays are available.
Maximum relay contact ratings:
• MT ICC 1600 SI-N: 30 VDC/1 A or 60 VDC/0.3
A.
• MT ICC 3000 SI-N: 30 VDC/16 A or 250
VAC/16 A.
Trigger input
The trigger input offers a way of externally con-
trolling the behavior of the device. The trigger
input can be connected to an external switch or a
potential free relay contact or activated by a short
piece of wire between both contacts. By closing
this external switch or contact, a user programma-
ble action will be performed. Such an action could
for example be to release the AC transfer switch,
temporarily disable the AC input power booster
feature or force the device to switch to inverter
mode.
By default, the device is preprogrammed to switch
to inverter mode for a limited time of 5 minutes
before switching off completely during an AC
power failure, if the trigger input is activated.
Number of trigger inputs:
• MT ICC 1600 SI-N: 1
• MT ICC 3000 SI-N: 2
Cleaning and maintenance
!
A
➤
Occasionally clean the product with a damp
cloth.
The device is maintenance-free.
Troubleshooting
Front panel error indications
When the mode indicator LEDs are blinking red, an
error has been detected.
➤
Observe the blinking patterns, chapter “Guide-
3
Mode indica-
tors
• Charger on
• Inverter on
• AC in
4
On/Off/Mode
button
• Automatic mode
(short push)
• Permanent mode (3s
push)
• Inverter off (another
short push)
NOTE
The “AC in”-LED corresponds to “Line”
fig.
i
,
page 16
Description
WARNING! Electrocution hazard
Always disconnect the mains plug before
you clean and service the device.
NOTICE! Damage hazard
Never clean the device under running
water or in dish washer. Do not use abra-
sive cleaning agents or hard objects
during cleaning as these can damage the
device.
Summary of Contents for BUTTNER MT ICC 1600 SI-N
Page 3: ...4445103626 3 1 126 mm 187 mm 334 mm...
Page 4: ...4 4445103626 2 287 mm 249 mm 37 mm 231 mm 144 mm 56 mm 5 mm...
Page 5: ...4445103626 5 3...
Page 6: ...6 4445103626 4...
Page 7: ...4445103626 7 2 3 1 5...
Page 8: ...8 4445103626 100 mm 100 mm 6...
Page 9: ...4445103626 9 7 58 mm 58 mm...
Page 10: ...10 4445103626 8 9...
Page 11: ...4445103626 11 0 a...
Page 12: ...12 4445103626 b INPUT OUTPUT AC INPUT AC OUTPUT L N L N A C D F G E B OUTPUT INPUT 1 2...
Page 13: ...4445103626 13 c d...
Page 14: ...14 4445103626 e 2x f 2 1...
Page 137: ...4445103626 137...
Page 138: ...138 4445103626...
Page 139: ...4445103626 139...