Page 16
Leak Sensor Advanced User Manual
Configuration Parameters Cont’d
Configuration Parameters Cont’d
Initial
Alarm
Alarm On
Alarm Off
Leak De-
tected
Total Alarm Duration
Mute Time
Mute Time
Mute Time
Reminder
Alarm
Reminder
Alarm
Figure 5 - Leak Sensor Alarm/Beeping behavior.
When the Leak Sensor detects a leak, it beeps intermittently in the pattern shown in Figure 5. Total
Alarm Duration, Mute Time, Initial Alarm, and Reminder Alarm duration times are all configurable
using Configuration Parameters 1, 2, 3, and 4 respectively.
Param
#
Size
Name
Available Values
Default
Value
01
This parameter sets the total amount of time the Leak Sensor will beep and light its LED in the event of a leak (see
Figure 5.)
01
Total Alarm Duration
00
(Leak Sensor beeps until water is removed)
01 ~ FF
(1 ~ 255 in Minutes)
78
(120 min)
02
This parameter defines the amount of time the Leak Sensor remains quiet between each Reminder Alarm (see Fig
5.)
01
Mute Time
01 ~ FF
(1 ~ 255 minutes)
01
(1 min)
03
This parameter sets the amount of time the Leak Sensor beeps before it is muted (see Fig 5.)
01
Initial Alarm
0A ~ FF
(10 ~ 255 seconds)
3C
(60 sec)
04
This parameter sets the length of each beep after the Initial Alarm (see Fig 5.)
01
Reminder Alarm
05 ~ FF
(5 ~ 255 seconds)
05
(5 sec)
Table 7 -
Configuration Parameters Continued