Page 12
Leak Sensor Advanced User Manual
Button Behavior
Action
Condition
Result
Press and hold
CONNECT BUTTON
for 2 seconds
Leak Sensor Already
Included in System
Device sends a wake up notification to its
controller, awaits further instructions, and blinks
the LED Indicator once
Push
CONNECT BUTTON
3 Times
Leak Sensor Already
Included in System
Device sends node info to Group 1
Leak Sensor Already
Included, and Controller is
in Exclusion Mode
Device is excluded from the system and removes
the Home ID from its memory
Leak Sensor Not Yet
Included in System, and
Controller is in Inclusion
Mode
Device enters inclusion mode and includes into
whichever network is also in inclusion mode
Press and hold
CONNECT BUTTON
for 10+ seconds
Leak Sensor Already
Included in System
Device will be reset to factory settings, and a
DEVICE_RESET_LOCALLY command will be sent to
Node 1
Press and Hold for
10+ seconds
Any condition (as long as
the device has power)
The device’s memory will erase to factory default
settings and any associations, configuration param
-
eters, and other locally saved data will be lost
Table 3 - Button Behavior