10.
DATA LOGGER
Press key longer than 2 seconds to enter or exit the function
Data Logging function is for Multimeter in Autoranging mode.
The Data Logger plots the measurement values versus time base in graph
display.
It allow to record up to 20 days of data with compressed and resizing to be
displayed on a full screen.
Logger function
Press key to select Volts/Ohms/Aux
If select Volts, press key to select “AC” “DC”
select Ohms, press key to select “Resistance” “Diode test” “Continuity”
“Capacitance”
select Aux, press key to select “ACA 1mV/A” “ACA 10mV/A” “DCA
1mV/A” “DCA 10mV/A” “deg C Temp” “deg F Temp” “Relative Humidity”
“psi” “Kpa”
USER
LOGGER
USER
LOGGER
9.
AUTO
AUTO function in SCOPE mode
Automatically adjust Volts/div, Time/div, Trigger Configure at best condition.
Set Time/div by counting Trigger Pulse and find Volts/div and select which
channel is base of Time/div.
AUTO function in METER mode
Autoranging function. If press, Autoranging mode changed to Manual ranging
mode. Default value of AUTO in SCOPE mode is as under.
Initial Set in AUTO
CH A Coupling
AC
-
CH 1 Probe
x1
-
CH A Invert
Off
-
CH A Position
0 div
-
CH B Coupling
AC
-
CH B Probe
x1
-
CH B Invert
Off
-
CH B Position
0 div
-
Time position
Center
-
Trigger Type
Edge
-
Trigger Edge
CH A
-
Trigger Edge Coupling
DC
-
Trigger Edge Slope
Rising
-
Cursor Type
Off
-
Math Type
Off
-
Auto set
Remark
10. DATA LOGGER
9. AUTO
64
Hand-held Digital Oscilloscope Meter
65